2.3
2.4
2.4.1
Siemens AG
Terminal strips in the Control Unit
The wiring of the terminal strip is displayed by way of an example for every type of
terminal.
If more than 6 digital inputs are required, use terminals 3 and 4 (AI 0) or terminals
10 and 11 (AI 1) as additional digital inputs DI 11 or DI 12.
1. Wiring when using the internal power supplies
DI = high if the switch is closed
2. Wiring when using the external power supplies
DI = high if the switch is closed
3. Wiring when using the internal power supplies
DI = low if the switch is closed
4. Wiring when using the external power supplies
DI = low if the switch is closed
Motor cable lengths and cross-sections
Cable specifications for conformity with EMC requirements
PM230
Cable type
Filter A
Shielded
Mounting and installation
Terminal strips in the Control Unit
EMC category
C2
2
Max. cable length
25 m (80 ft)
9
CM2G5111en
2014-05-16