Configuration Procedure - Huawei Quidway S2700 Series Configuration Manual

Hide thumbs Also See for Quidway S2700 Series:
Table of Contents

Advertisement

Quidway S2700 Series Ethernet Switches
Configuration Guide - Network Management
Figure 7-1 Networking diagram of configuring RMON
Configuration Roadmap
To send a Trap message to the NMS, you need to use SNMP commands to enable the Trap
function and set a corresponding community name. For details, refer to the chapter SNMP
Configuration.
The configuration roadmap is as follows:
l
l
l
l
l
Data Preparation
To complete the configuration, you need the following data:
l
l
l

Configuration Procedure

1.
2.
Issue 01 (2011-07-15)
IP
Network
NMS
Enable the statistics function.
Configure the etherStatsTable.
Configure the historyControlTable.
Configure the eventTable.
Configure the alarmTable.
Interval for sampling data
Threshold for triggering alarms
Community name for communicating with the NMS
Configure reachable routes between the Switch and the NMSs. The configuration procedure
is not mentioned.
Enable the statistics function.
# Enable the RMON statistics function on the interface.
<Switch> system-view
[Switch] interface ethernet 0/0/1
[Switch-Ethernet0/0/1] rmon-statistics enable
# Configure the etherStatsTable.
[Switch-Ethernet0/0/1] rmon statistics 1 owner User01
# Verify the configuration. You can check the traffic on the subnet.
[Switch-Ethernet0/0/1] display rmon statistics ethernet 0/0/1
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Ethernet
0/0/1
Switch
7 RMON Configuration
PC
PC
VLAN
341