Huawei Quidway S2700 Series Configuration Manual page 175

Hide thumbs Also See for Quidway S2700 Series:
Table of Contents

Advertisement

Quidway S2700 Series Ethernet Switches
Configuration Guide - Network Management
After the previous configuration, check information about the administrator switch and member
switches in the cluster on the administrator switch. You can find that all the member switches
are added to the cluster and in the Up state.
[HUAWEI_0.Administrator-1-cluster] display cluster members
The list of cluster member:
------------------------------------------------------------------------------
SN
------------------------------------------------------------------------------
0
1
2
3
Step 7 Assign an IP address to VLANIF 10.
# To ensure the normal communication between member switches in the cluster and devices out
of the cluster, assign an IP address to VLANIF 10 on the administrator switch.
# Assign an IP address to VLANIF 10.
[HUAWEI_0.Administrator-1] interface vlanif 10
[HUAWEI_0.Administrator-1-Vlanif10] ip address 1.0.0.1 8
[HUAWEI_0.Administrator-1-Vlanif10] quit
After the previous configuration, you can find that the interface on the administrator switch is
in the Up state.
[HUAWEI_0.Administrator-1] display interface Vlanif 10
Vlanif10 current state : UP
Line protocol current state : UP
Description:HUAWEI, Quidway Series, Vlanif10 Interface
Route Port,The MTU is 1500
Internet Address is 1.0.0.1/8
Internet Address is 10.0.0.1/8 Cluster
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 0001-0001-0001
Step 8 Configure a static route on the administrator switch.
# This operation is to ensure that a reachable route exists between switches in the cluster and
servers or hosts.
[HUAWEI_0.Administrator-1] ip route-static 0.0.0.0 0 1.0.0.2
Step 9 Configure public servers and hosts of the cluster.
# Configure an FTP server.
[HUAWEI_0.Administrator-1] cluster
[HUAWEI_0.Administrator-1-cluster] cluster-ftp-nat enable
[HUAWEI_0.Administrator-1-cluster] ftp-server 2.0.0.1
# Configure a SFTP server.
[HUAWEI_0.Administrator-1-cluster] sftp-server 2.0.0.2
# Configure a Simple Network Management Protocol (SNMP) host.
[HUAWEI_0.Administrator-1-cluster] snmp-host 3.0.0.1
# Configure a log host.
[HUAWEI_0.Administrator-1-cluster] logging-host 4.0.0.1
Issue 01 (2011-07-15)
Device Type
S2700
S2700
S2700
S2700
Input bandwidth utilization
Output bandwidth utilization : --
NOTE
You can also run a routing protocol.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
MAC Address
Status Device Name
0001-0001-0001
Admin
0002-0002-0002
Up
0003-0003-0003
Up
0004-0004-0004
Up
: --
3 HGMP Configuration
HUAWEI_0.Administrator-1
HUAWEI_1.Member-1
HUAWEI_2.Member-2
HUAWEI_3.Member-3
165