Furuno DS-60 Installation Manual page 8

Doppler sonar
Hide thumbs Also See for DS-60:
Table of Contents

Advertisement

1. INSTALLATION
2. Make four pilot holes for self-tapping screws (diameter: 5 mm) in the location in-
dicated in the illustration on "Flush Mount" on page 1-1.
3. Insert the sponge to the display unit from the rear side.
4. Set the display unit to the cutout and fasten the display unit with four self-tapping
screws (5x20).
5. Set a cosmetic cap to each fixing hole on the front panel. See page 1-3.
Desktop or table underside mount
The display unit can be mounted on a desktop or on the underside of a table using the
optional hanger. See the outline drawing for details.
Hanger assembly (Type: OP26-8, Code No.: 000-016-313-00)
Name
Self-tapping screw
Binding head screw
Hanger Assembly
1. Remove the hanger mounting plate from the hanger assembly.
2. Fasten the hanger mounting plate to the display unit from the left side and right
side with four binding head screws (M5x12).
Hanger mounting
plate (left side)
3. Make a four pilot holes for self-tapping screws (5x20) in the mounting location.
4. Fix the hanger to the mounting location with four self-tapping screws (5x20).
5. Screw knobs into the display unit loosely.
6. Set the display unit to the hanger.
7. Tighten the knobs to fasten the hanger to the display unit.
1-2
Type
5x20
M5x12
OP26-8-1
Code No.
000-171-997-10
000-171-999-10
001-081-920-00
Screw (M5x12)
Qty
4
4
1