REPLACEMENT OF COOLING FLUID

Place a vessel on the L.H. side of the cylinder, under the Piping (1).
Remove the exhaust pipe (a). Loosen the pipe strap (2) of the piping
(1), take the pipe off the fitting that secures it to the engine, then
SLOWLY open the R.H. radiator cap (3); slope the motorcycle on the
left side to drain the coolant easily in the vessel.
Once over, fit the pipe back in (1) and secure it with the strap (2).
Fit the exhaust pipe back in.
Pour the necessary quantity of coolant in the radiator then warm up
the engine in order to eliminate any possible air bubble.
1
Periodically check the connecting hoses (see "Periodical main-
tenance card"): this will avoid coolant leakages and consequent
engine seizure: If hoses (A) show cracks, swelling or hardenings
due to sheats desiccation, their replacement shall be advisable.
Check the correct tightening of the clamps (B).
a
2
A: Piping
B: Clamps
B
3
A
A
A
B