3. SERVICE TABLES

3.1 DIP SWITCH SETTINGS

The DIP switches should not be set to any combination other than those described
in the table below.
DPS101
1
2
3
4
0
0
0
0
Default.
1
1
1
0
Free run.
0
0
0
1
Transportation
NOTE: The following procedure repositions the shift trays to the shipping position.
1) Make sure that the main switch is turned off.
2) Turn on DIP SW101-4 on the main board.
3) Turn on the main switch.
4) After the fisher completes the initialization, turn off DIP SW101-4.
Finisher automatically repositions the shift trays to the shipping position.

3.2 TEST POINTS

No.
Label
TP101
GND
TP102
5 V
TP103
RXD
TP104
TXD

3.3 FUSES

No.
FU101
Protects 24 V.
SM
Mode
No paper.
See the note below.
Monitored Signal
Ground
5 V
Received command data
Transmitted command data
Function
13
DIP SWITCH SETTINGS