CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

Group 0: User Parameters
Parameters
Identity code of drive
0-00
(Read only)
Rated current display
0-01
(Read only)
0-02
Parameter reset
0-03
Start-up display of AC
drive
0-04
User-defined Unit
0-05
User-defined coefficient
K
0-06
Software version
0-07
Password input
0-08
Password configuration 0 ~ 999
Group 1: Basic Parameters
Parameters
Maximum operation
1-00
Freq.
1-01
Maximum setting Freq.
1-02
Maximum output voltage 2.0 ~ 255V
1-03
Mid-point freq.
1-04
Mid-point voltage
1-05
Minimum output freq.
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
The parameter may be set during operation.
Functions
1: 40W
2: 100W
3: 200W
4: 400W
5: 750W
6: 1.5KW
40W: 0.4A
100W: 0.8A
200W: 1.6A
400W: 2.5A
750W: 4.2A
1.5K: 7.0A
10: Reset Parameters to Factory Setting
0: F (Frequency command)
1: H (output frequency)
2: U (user-defined unit)
3: A (output current)
0: Display User-Defined Unit (u)
1: Display Counter Value (C)
2: Display Process Operation (1=tt)
3: Display DC-BUS voltage (U)
4: Display output voltage (E)
0.1 ~ 160
Read only
0 ~ 999
Functions
50.0 ~ 400Hz
10.0 ~ 400Hz
1.0 ~ 400Hz
2.0 ~ 255V
1.0 ~ 60.0Hz
Settings
Settings
8-1
VFD-L Series
Factory
Setting
0
0
0
8
1.0
#.#
0
0
Factory
Setting
60.0
60.0
220
1.0
12.0
1.0