Delta VFD-L User Manual

Delta VFD-L User Manual

Variable speed ac motor drive 115v/230v 25w – 100w high performance / easy control ac drive

Advertisement

User Manual
ASIA
DELTA ELECTRONICS, INC.
TAOYUAN Plant/
31-1, SHIEN PAN ROAD,
Termoprocesos e Instrumentacion S.A de C.V
KUEI SAN INDUSTRIAL ZONE
Filosofos #301 Dep. 101-A Col. Tecnologico
TAOYUAN 333, TAIWAN
Monterrey, N.L., Mexico
TEL: 886-3-362-6301
Tel. (81) 8359-6229 y (81) 8359-6130
FAX: 886-3-362-7267
Fax. (81) 8358-3777
http://www.deltaww.com/acdrives
Correo: ventas@termoprocesos.com
www.termoprocesos.com - www.termo-tienda.com
HIGH PERFORMANCE / EASY CONTROL AC DRIVE
NORTH/SOUTH AMERICA
DELTA PRODUCTS
CORPORATION
Sales Office/
P.O. BOX 12173
5101 DAVIS DRIVE
RTP, NC 27709 U. S. A.
TEL: 1-919-767-3813
FAX: 1-919-767-3969
http://www.deltaww.com/acdrives
VARIABLE SPEED AC MOTOR DRIVE
115V/230V
EUROPE
DELTRONICS (Netherlands) B.V.
Sales Office/
Industriegebied Venlo Nr. 9031
Columbusweg 20
NL-5928 LC Venlo
The Netherlands
TEL: 31-77-324-1930
FAX: 31-77-324-1931
V
F
D
-
L
V
F
D
-
L
25W – 100W

Advertisement

Table of Contents
loading

Summary of Contents for Delta VFD-L

  • Page 1 User Manual VARIABLE SPEED AC MOTOR DRIVE 115V/230V 25W – 100W HIGH PERFORMANCE / EASY CONTROL AC DRIVE ASIA NORTH/SOUTH AMERICA EUROPE DELTA ELECTRONICS, INC. DELTA PRODUCTS DELTRONICS (Netherlands) B.V. TAOYUAN Plant/ CORPORATION Sales Office/ 31-1, SHIEN PAN ROAD, Sales Office/ Industriegebied Venlo Nr.
  • Page 2: Receiving And Inspection

    Receiving and Inspection This VFD-L AC drive has gone through rigorous quality control tests at the factory before shipment. After receiving the AC motor drive, please check for the following: Receiving Check to make sure that the package includes an AC drive and the User Manual.
  • Page 3 Wait five minutes for DC bus capacitors discharge. Any Electrical or mechanical modification to this equipment without prior written consent of Delta Electronics, Inc. will void all warranties and may result in a safety hazard in addition to voiding the UL listing.
  • Page 4 10cm 10cm 10cm 10cm 10cm 13.5cm Connections: Installations intended to meet UL and CUL requirements must follow the instructions provided in “Wiring Notes” section below as a minimum standard. Where local codes exceed these requirements, they must also be followed. Refer to the technical data label affixed to the AC drive and the motor nameplate for electrical data.
  • Page 5 Main Circuit Terminals: wire gauge 22-14AWG, torque 10kgf-cm (8.7 in-lbf) Terminal Symbols Terminal Functions L/L1, N/L2 AC line input terminals U/T1, V/T2, W/T3 Motor connections Earth Ground Control Circuit Wiring: wire gauge 22-14AWG, torque 10kgf-cm (8.7 in-lbf) Terminal Terminal names Remarks symbols Normally Open contact, AC drive starts...
  • Page 6 Switch Setting Descriptions: The DIP Switches can only be changed when AC drive is in a stopped mode. Indicates the position of the switch (ON/OFF). Switch Parameter Descriptions Switch Setting Switch Name Maximum Output Frequency V/F Curve 100% 50Hz 1 2 3 4 5 6 7 50Hz 100% Max.
  • Page 7: Computer Controls

    10-bits character frame AC Drive Addresses for RS-485 Communication VFD-L series communication addresses are 1 to 63, since 0 means broadcast to all AC drives. A DIP Switch sets to ON for equal to 1 and OFF for equal to 0.
  • Page 8: Communication Protocol

    (B) The addresses will remain in memory when parameters are reset. To save new addresses, remove power from the drive, set DIP switch 7 to ON and reapply power to the drive, at this time the new addresses will be read. Examples of setting up the address (Black block means ON or OFF of DIP SWITCH): Communication Communication...
  • Page 9 ‘2’ ‘0’ ‘2’ ‘2’ Number of data (byte) ‘1’ ‘4’ ‘0’ ‘0’ Starting data ‘0’ Content of ‘1’ ‘0’ ‘0’ Data address Data address address starting data ‘7’ address ‘2’ ‘7’ ‘1’ ‘1’ 2102H ‘0’ Number of ‘0’ ‘0’ ‘1’ ‘1’...
  • Page 10 Parameters (saved in the EEPROM) : the parameter can be set during the operation. Factory Parameter Parameter Function Parameter Setting Customer Setting Setting Identity code of Drive Depend on drive Read only Rating current Depend on drive Read/Write Parameter Reset 10: Reset Read/Write 0: 50 Hz...
  • Page 11 Content: Address: Function: Error Codes 00: No error occurred 01: Over-current (oc) 02: Over-voltage (ov) 03: Overheat (oH) 04: Overload (oL) 05, 06: Reserved 07: CPU failure (cF3) 08 to 13: Reserved 14: Low voltage (Lv) 2100H 15: CPU failure 1 (cF1) 16: CPU failure 2 (cF2) 17 to 19: Reserved 20: Software protection...
  • Page 12: Exception Responses

    Exception Responses: Except for broadcast messages, the AC drive is been expected to return a normal response after receiving command messages from the master device. The following depicts the conditions that no normal response is replied to the master device. The AC drive does not receive the messages due to a communication error;...
  • Page 13 Maintenance and Inspections Modern AC drives are based on solid state electronics technology, preventive maintenance is required to operate this AC drive in its optimal condition, and to ensure a long life. It is recommended to perform a monthly check up of the AC drive by a qualified technician. Before the check up, always turn off the AC Input Power to the unit.
  • Page 14 Troubleshooting and Fault Information The AC drive has a comprehensive fault diagnostic system that includes several different alarms and fault message. Once a fault is detected, the corresponding protective functions will be activated to shut down the AC drive output. Below are the fault descriptions, for a fault shown on the AC drive digital keypad.
  • Page 15: Standard Specifications

    Standard Specifications Voltage Class 115V Class 230V Class Model Number VFD- Weight g (lb) A (standard) 270 (0.60) 440 (0.97) 260 (0.57) 430 (0.95) Weight g (lb) B (build-in EMI filter) 350 (0.77) 525 (1.16) 340 (0.75) 510 (1.12) Max. Applicable Motor Output (W) 25/40 60/100 25/40...
  • Page 16 Dimensions VFD40WL11A VFD40WL21A VFD001L11A VFD001L21A 2.7 [0.11] 8.0 [0.31] 125.1 [4.93] Unit: mm [inch] 60.0 [2.36] 135.7 [5.34] 52.5 [2.07] PO W E R A L AR M H ig h L/L1 N/L2 Lo w U/T1 V/T2 W/T3 S T O P R U N FW D R E V...

Table of Contents