Status monitor
Read only
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Address
2100H
11: Current exceeds 2 times rated current
during steady state operation (ocn)
12: Reserved
13: Reserved
14: Low voltage (Lv)
15: CPU failure 1 (cF1)
16: CPU failure 2 (cF2)
17: Base block
18: Overload (oL2)
19: Auto accel/decel failure (cFA)
20: Software protection enable (codE)
Status of AC Drive
2101H
Bit 0-1
Bit 2
Bit 3-4
Bit 5-7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12-15
2102H
Frequency command F (XXX.XX)
2103H
Output Frequency H (XXX.XX)
2104H
Output Current A (XXX.XX)
2105H
DC-BUS Voltage U (XXX.XX)
2106H
Output Voltage E (XXX.XX)
2107H
Step number of Multi-Step Speed Operation
2108H
Step number of PLC operation
2109H
Time of PLC Operation
210AH
Counter Value
5-49
Functions
00: RUN LED light off, STOP LED light up
01: RUN LED blink, STOP LED light up
10: RUN LED light up, STOP LED blink
11: RUN LED light up, STOP LED light off
01: Jog active
00: REV LED light off, FWD LED light up
01: REV LED blink, FWD LED light up
10: REV LED light up, FWD LED blink
11: REV LED light up, FRD LED light off
Not used
1: Main freq. Controlled by
communication
1: Main freq. Controlled by external
terminal
1: Operation command controlled by
communication
1: Parameters have been locked
Not Used
VFD-L Series
5