Alarm
Alarm text on the
no.
display
E53
S. fault Tho-S
E54
S. fault LPT
E57
Low refrigerant
E59
Inverter error
Description
Sensor fault, suction gas in outdoor unit (Tho-S).
Sensor fault, low pressure sensor in outdoor unit.
Insufficient refrigerant is detected at initial startup
in cooling mode.
Compressor fails to startup for 14 times
(7 patterns × 2 times)
May be due to
- Open-circuit or short-circuit on sensor input
- Sensor does not work (see "Temperature sensor"
section)
- Defective control PCB in outdoor unit
Also see the troubleshooting guide on page 174.
- Open-circuit or short-circuit on sensor input
- Sensor does not work (see "Temperature sensor"
section)
- Defective control PCB in outdoor unit
- Fault in the refrigerant circuit
Also see the troubleshooting guide on page 175.
- Service valve closed
- Loose connection of sensor (BT15 or BT3)
- Defective sensor (BT15 or BT3)
- Insufficient amount of refrigerant
Also see the trouble shooting guide on page 176.
- Defective outdoor fan motor
- Defective inverter PCB in outdoor unit
- Compressor fault
- Incoming power supply interference
Also see the trouble shooting guide on page 177.