Mitsubishi HMA100V Technical Manual page 287

Air to water heat pump
Hide thumbs Also See for HMA100V:
Table of Contents

Advertisement

Technical specifications
Specifications
Indoor Model
Outdoor Model
Power source
Heating Nominal capacity
Heating power consumption
COP
Cooling Nominal capacity
Cooling power consumption
EER
Tapping capacity
Operation range
(Outdoor temperature)
Operation range
(Water temperature)
System water flow
Max current
Recommended fuse rating
Starting current
Deviation, incoming supply
Max refrigerant pipe length
Max height difference between IU and OU
Height
Width
Depth
Weight (without water in the system)
Color
IP Grade
Immersion heater
Output
Max available external pressure
Max flow
Flow at 20kPa pressure drop
Emergency mode thermostat
Temperature limiter
Safety valve
Volume total
Volume hot water coil
Material hot water coil
Max pressure, tank
Max pressure, hot water coil
Water quality, domestic hot water
Volume expansion vessel
Ambient temperature, indoor module
Dimensions, climate system pipe
Dimensions, hot water pipe
Water pipe connection
External heat source connection
HMA100V
1 phase 230V 50Hz/
3 phase 400V 50Hz
condition 1
kW
condition 2
kW
condition 1
kW
condition 2
kW
condition 1
condition 2
condition 1
kW
condition 2
kW
condition 1
kW
condition 2
kW
condition 1
condition 2
12liter/min
liter
16liter/min
liter
heating
cooling
heating
cooling
l/s
A
A
A
m
m
mm
mm
mm
kg
W
bar
l/s
l/s
bar
liter
liter
bar
bar
liter
mm
mm
HMA100VM
HMA100V
FDCW71VNX
1 phase 230V 50Hz/
3 phase 230V 50Hz
3 phase 400V 50Hz
8.0 (3.0 - 8.0)
8.3 (2.0 - 8.3)
2.40
2.03
3.33
4.08
7.1 (2.0 - 7.1)
10.7 (2.7 - 10.7)
2.65
3.19
2.68
3.35
270
200
25 - 58 (65 with immersion heater)
7 - 25
0.19 - 0.38
44/
30
16
50/
32
16
30
7
1760 (+20 - 50mm, adjustable feet)
600
650
140
9kW 4steps (2, 4, 6, 9)
9-63 (variable speed)
0.57
0.54
0.45
35/45
98(-8)
2.5
270 ±5%
14
Stainless steel
2.5
10.0
≦ EU directive no 98/83/EF
22
22
Compression fittings
ISO 228/1 G1 internal
- 7 -
'10 • HM-T-149A
Specifications
HMA100VM
FDCW100VNX
FDCW140VNX
1 phase 230V 50Hz/
3 phase 230V 50Hz
3 phase 400V 50Hz
9.0 (3.5 - 12.0)
16.5 (5.8 - 16.5)
9.2 (3.5 - 10.5)
16.5 (4.2 - 17.2)
2.50
2.07
3.60
4.44
8.0 (3.0 - 9.0)
11.0 (3.3 - 12.0)
16.5 (5.2 - 16.5)
2.85
3.04
2.81
3.62
270
200
-20 - 43
15 - 43
0.24 - 0.57
44/
30
16
50/
32
16
5
-15 - +10%
12
White
IP21
9-110 (variable speed)
5-35, RH95%
Technical data
HMS140V
4.98
3.93
3.31
4.20
4.60
3.59
18-25
0.40 - 0.79
50/
25
63/
25
30
1004
513
360
60
0.61
0.78
0.67
18
28
59