Menu 9.1.8 [S] Min CompFreq act/set
Select the min compressor frequency here. Both actual and set
values are shown.
FDCW71
Setting range (Hz)
20 – 86
Default value (Hz)
Menu 9.1.9 [S] Max CompFreq act/set
Select here the max limit for the compressor. Both actual and
set values are shown.
FDCW71
Setting range (Hz)
20 – 118
Default value (Hz)
Menu 9.1.10 [S] OU Cur. heat act/max
The phase current to outdoor unit is shown and the highest
permitted current in heating mode can be set here.
FDCW71
Setting range (Hz)
TBD
Default value (Hz)
TBD
Menu 9.1.11 [S] OU Cur. cool act/max
The phase current to outdoor unit is shown and the highest
permitted current in cooling mode can be set here.
FDCW71
Setting range (A)
TBD
Default value (A)
TBD
Menu 9.1.12 [S] Tank defrost Temp.
If the system is colder than the set value during defrosting,
connecting to HW. If HW is colder, the electric heater starts.
Menu 9.1.13 [S] Return
Return to Menu 9.1.0.
Menu 9.2.0 [S] Add. heat settings
Settings regarding additional heat, shunt in HM 270V and any
extra shunt can be made in the sub-menus to this menu.
Menu 9.2.1 [S] DM start add. heat
The degree minute deficit to activate additional heat supply is
set here.
Setting range: -1000 – -30
Default value: -400
Menu 9.2.2 [S] Time factor
The time factor of the immersion heater since first start up is
shown here. The value is saved and is not reset even when the
boiler is switched off using the main power switch.
Menu 9.2.3 [S] Docking type
No function.
FDCW100 FDCW140
20 – 80
20 – 77
20
20
20
FDCW100 FDCW140
25 – 85
20 – 120
118
85
120
FDCW100 FDCW140
7 – 17
7 – 25
15
24
FDCW100 FDCW140
7 – 17
7 – 23
15
22
Menu 9.2.4 [S] Reg. amplification
P section for additional heat control.
Setting range: 0 – 10.0
Default value: 1.5
Menu 9.2.5 [S] Reg. integrator time
I section for additional heat control.
Setting range: 5 – 60
Default value: 10
Menu 9.2.6 [S] Shunt amplification
Applies to shunt 1 (QN11). E.g. 2 degrees difference and 2 in
amplification gives 4 sec/min controlling the shunt.
Setting range: 0.1 – 5.0
Default value: 1.0
Menu 9.2.7 [S] Shunt amplification2
Applies to any heating system 2 (accessory required). E.g. 2
degrees difference and 2 in amplification gives 4 sec/min
controlling the shunt. This function compensates for the speed
variation found on different shunt motors that may be installed.
Setting range: 0.1 – 5.0
Default value: 1.0
Menu 9.2.8 [S] Add. heat type
Select the type of additional heat source to be used.
Setting range: Internal power, Ext. 1 step, Ext. Lin 3, Ext. Bin 3,
Internal power 2
Default value: Internal power (other models)
Internal power 2 (HMA100VM)
Menu 9.2.9 [S] Return
Return to Menu 9.2.0.
Menu 9.3.0 [S] Operating settings
Settings regarding accessories, additional heat operation, floor
drying and a return to the factory settings can be made in the
sub-menus to this menu.
Menu 9.3.1 [S] Max. boiler temp.
The setting selected on the PCB (AA22) knob (R26) is shown
here.
Menu 9.3.2 [S] Logger
Select "On" here if logger is installed.
Setting range: Off, On
Default value: Off
Menu 9.3.3 [S] Cooling system
Select "On" if cooling system is installed (accessory required).
Setting range: Off, On
Default value: Off