Mitsubishi HMA100V Technical Manual page 285

Air to water heat pump
Hide thumbs Also See for HMA100V:
Table of Contents

Advertisement

Comfort setting hot water
The integrated water heater is a coil model and is heated by
circulating water, which is heated by the heat pump.
During "normal" consumption it is enough to run the heat
pump to supply the different tapping points of the house with
hot water. The temperature of the hot water in the water heater
then varies between the set values.
Under section 1.0 [N] Hot water temp. on page 93 there is a
complete description of menu settings for hot water
temperatures.
Available volume
<HMA100V, HMA100VM>
600
500
400
300
200
100
0
50
53
56
Stop temp. HW (°C )
<HMS140V>
* This graph is based on the following conditions :
MT300
Inlet water temperature : 15°C
Outlet water temperature : 40°C
Outdoor air temperature : 7°C
450
Start temp. HW setting :
55°C (Stop temp. HW setting is 58°C or higher)
400
Stop temp. HW -3°C (Stop temp. HW setting is
lower than 58°C )
350
300
250
200
150
100
50
0
50
53
56
Stop temp HW (°C)
Hot water Supply is unlimited in case 8 ℓ /min at the condition
as the capacity is bigger than hot water supply.
Hot water volume
8ℓ/min
12ℓ/min
16ℓ/min
59
62
65
Hot water volume
12 ℓ /min
16 ℓ /min
59
62
65
600
MT500
500
1600
1400
400
1200
300
1000
800
200
600
400
100
200
0
0
50
48
50
53
52
* This graph is based on the following conditions :
Inlet water temperature : 15°C
Outlet water temperature : 40°C
Outdoor air temperature : 7°C
Start temp. HW setting :
Hot water Supply is unlimited in case 8 ℓ /min at the condition as
55°C (Stop temp. HW setting is 58°C or higher)
the capacity is bigger than hot water supply.
Stop temp. HW -3°C (Stop temp. HW setting is
lower than 58°C )
Prioritizing
When the water temperature in the tank drops, heat pump
operation shifts to hot water production. In case there is
demand for both hot water and heating/cooling for long time,
operation mode is periodically switched between hot water and
heating/cooling. For details, see Menu 1.0 Hot water temp and
Menu 8.5.0 Period settings.
Extra Hot Water
In all "Extra hot water" functions, the temperature of the hot
water increases temporarily. The temperature is first increased
to an adjustable level by the compressor (Menu 1.5) and then
the electric heater is energized until the water temperature
reaches the stop temperature (Menu 1.4).
Temporary "Extra hot water" is activated manually, whilst time
based extra hot water is activated using the settings made in the
control computer.
When:
■ "A" appears above the
is active.
■ "B" appears above the
is active.
NOTE
" Extra hot water" usually means that the electric heater
is activated regardless of Allow add heat setting (menu
8.2.1) and therefore increases the electrical
- 48 -
'10 • HM-T-149A
For Home Owners
Comfort setting hot water
Hot water volume
Hot water volume
54
56
56
59
58
60
62
62
64
Stop temp. HW(°C)
Stop temp. HW (°C )
icon, temporary extra hot water
icon, time based extra hot water
consumption.
8ℓ/min
10 ℓ /min
12ℓ/min
12 ℓ /min
16ℓ/min
14 ℓ /min
16 ℓ /min
24 ℓ /min
65
57