Mitsubishi HMA100V Technical Manual page 290

Air to water heat pump
Hide thumbs Also See for HMA100V:
Table of Contents

Advertisement

Radiators - only heating
HMA100V - FDCW100VNX (71VNX)
20S
4-way valve
63H1
High pressure switch
CM
Compressor motor
CT
Current sensor
EEV-C
Expansion valve, cooling
EEV-H
Expansion valve, heating
FMo1
Fan motor
LPT
Low pressure sensor
Tho-A
Temperature sensor, outdoor air
Tho-D
Temperature sensor, hot gas
Tho-R1
Temperature sensor, heat exchanger out
Tho-R2
Temperature sensor, heat exchanger in
Tho-S
Temperature sensor, suction gas
Function
The heat pump prioritises hot water charging. The compressor
output is adjusted according to the outdoor temperature. The
circulation pump varies the flow to maintain a high charge
temperature.
When the water heater is full, the valves QM30 and QM31
switch to the heating system. The heat pump is then controlled
by a calculated set point value on the flow line. The compressor
varies the output according to the demand. The circulation
pump runs at a fixed set speed.
If the compressor does not manage the entire heat demand, the
electric heater is activated if it is allowed by setting and the
heat shunted out on the flow line.
Heating mode
QM30
Closed
QM31
Open
QN11
Active during balance point (A)
Hot water mode
QM30
Open
QM31
Closed
QN11
Open (AB)
BP4
High pressure sensor
BP5
Pressure gauge
BT1
Temperature sensor, outdoor air (external)
BT2
Temperature sensor, supply
BT3
Temperature sensor, heat exch. in (Twin)
BT6
Temperature sensor, tank water
BT12
Temperature sensor, heat exch. out (Twout)
BT15
Temperature sensor, liquid pipe (Thi-L)
BT19
Temperature sensor, immersion heater
BT24
Temperature sensor, external heat source
BT30
Thermostat, standby mode
CM1
Expansion vessel
CP1
Buffer vessel
CW
Sanitary cold water inlet
EB1
Immersion heater
EP2
Heat exchanger
FD1
Temperature limiter
FL1
Safety valve, HW
FL2
Safety valve, tank
FQ1
Mixing valve, HW
GP1
Circulation pump, climate system
GP10
Circulation pump, external 1
HQ1
Strainer (water)
HS1
Filter dryer (refrigerant)
HW
Sanitary hot water outlet
MH-RG10
Room sensor MH-RG10 (accessory)
QM30
Reversing valve, hot water
QM31
Reversing valve, climate system
QN11
Mixing valve
Installation requirements
See page 9.
- 112 -
'10 • HM-T-149A
System description
Radiators - only heating
0-4.15
MPa
0-4 Bar
(enclosed)
φ11
35-45℃ adjustable
9kW (3-phase)
98℃
2.5 Bar
variable flow
0.8mm2
bi-flow 083
2-way 35sec
2-way 35sec
3-way ball type 35sec
62

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents