Mitsubishi HMA100V Technical Manual page 194

Air to water heat pump
Hide thumbs Also See for HMA100V:
Table of Contents

Advertisement

FDCW100VNX
Compressor (CM)
9. Untie the strings and remove
the insulations
10. Unscrew and disconnect
the grounding cable
11. Loosen 3 nuts of
compressor fixing bolts
12. Disconnect the pipes for
suction and discharge gas
13. Remove the compressor
Control PCB (PWB1)
1. Unscrew and disconnect
the cable
2. Cut the straps and take the
cable out from CT hole as
shown in the photo.
Note: Be sure to do this
work after elapsing
3 minutes from
power OFF.
Upper insulation
Lower insulation
Screw for
grounding
Suction gas pipe Discharge gas pipe
- 193 -
'10 • HM-T-149
Component replacement
3 nuts of compressor
3 nuts of compressor
fixing bolts
Crankcase heater
1 screw
2 straps
Service

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents