Furuno FCR-2127 Installation Manual page 62

Marine radar/arpa
Hide thumbs Also See for FCR-2127:
Table of Contents

Advertisement

3. SETTING AND ADJUSTMENT
Radar Number
For multiple radar system using the network hub, set number (name) of the radar.
Radar
Set antenna position of the radar to easily distinguish the radar configuration among MAIN
TOP, MAIN 2nd, MAIN 3rd, AFT, PORT STRD and FORE.
Model
Confirm the model of your radar. If the setting of this item is different from your model
(combination of the antenna unit), the radar functions abnormally.
12:
For FCR-2117/2817
25 UP: For FCR-2127/2827
On Time and TX Time
These items show number of hours the radar has been turned on and transmitted,
respectively. Value can be changed; for example, after replacing magnetron TX Time can be
reset to 0.
PM Gain Adj
Note: If you install the Performance Monitor PM-31 at field, see section 4.2 on page 4-9.
When you choose this item, the radar setting changes as follows.
RANGE:
PULSE:
BLIND SECTOR:
STC:
RAIN:
ECHO AVERAGE:
VIDEO CONTRAST: B2
TUNE:
1. Adjust the GAIN control so that a slight amount of white noise appears on the screen.
Arcs for performance monitor appear on the screen (Fig.1).
2. Adjust PM Gain Adj so that outer arc just disappears (Fig.2). The setting range is 0 to
255.
Fig.1
3-16
24 NM
LONG
OFF
OFF by Manual
OFF by Manual
OFF
AUTO
13.5 - 18.5 nm
Approx. 0.6 nm
(10 dB)
13.5 - 18.5 nm
Fig.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcr-2117Fcr-2817Fcr-2127-bbFcr-2827Fcr-2117-bb

Table of Contents