3.3

Setting IP Address

Running Windows
The chart processor unit has two local area network interfaces. To set the IP Address, run
WindowsXP as follows.
1. Insert the service keyboard to the front panel of the chart processor unit.
2. Turn the chart radar on.
3. While pressing down the Alt key, press the Tab key on the service keyboard several
times to show ECAWATCH window.
4. Release the keys and press the "Shutdown the ECDIS" button on the screen
immediately.
5. Press the Alt and F4 keys simultaneously. Now WindowsXP screen appears.
Local Area Connection for LAN 1 (ARPA Radar Network)
To configure IP Address for Local Area Connection interface, proceed as follows:
1. Open the Control Panel of the Windows.
2. Double click Network Connection icon.
3. Highlight "Local Area Connection1", and then select Properties in File menu.
4. In "Local Area Connection1 Properties", highlight Internet Protocol (TCP/IP), and then
press the Properties button.
5. Set IP Address as 172.31.3.33 (default) or 172.31.3.34 (for the second Chart radar).
6. Set Subnet mask as 255.255.0.0.
7. Press the OK button to close the window.