3. SETTING AND ADJUSTMENT
3.10

Saving and Restoring Radar Initialize Parameters

Saving or restoring on hard disk of Chart radar
Radar initialize parameters can be saved on hard disk of Chart processor when you have
set correct operative parameters. They can then be restored when ever it is required.
To save parameters:
1. Connect the USB memory which contains "service.pas" file. If you do not have a USB
memory, enter the password to access to the menu. When the window for password
appears on the display, enter "6", "1", "4", "2" ("M+GA" shown on the display), and click
the left button and the OK button to show the installation parameters menu.
2. Press the MENU key on the control unit to show the Main Menu.
3. Roll the wheel to choose "Initial Settings" to show INITIAL SETTINGS dialog box.
4. Rotate the trackball to place the cursor on the
appears.
3-20
INITIAL SETTINGS
Set values
Datum
WGS 84
Position
discrepancy limit
0.00
nm
[ Initial Settings ]
Function keys
Operation
Installation params
Priority Alert
Chart Alert params
Radar Initialize
Nav params
Selftest
TT Test
Close
mark. The "Initial Settings" menu