Optimizing The Powder Cloud For Your Coating; Recommended Settings For Total Air Volume - WAGNER PEM-X1 Operating Manual

Powder spray gun
Table of Contents

Advertisement

VERSION 03/2014
OPERATING MANUAL
7.3

OPTIMIZING THE POWDER CLOUD FOR YOUR COATING

Procedure:
1. Switch on the high-voltage generation and the powder feed.
Note:
To minimize wear on the wearing parts, the total air volume should be below 5 Nm³/h!
The atomizing air should be adjusted for the:
fan spray nozzle to 0.1 Nm³/h,
round spray nozzle to > 0.2 Nm³/h
2. Adjust the powder quantity and the powder speed on a test piece.
7.3.1

RECOMMENDED SETTINGS FOR TOTAL AIR VOLUME

Hose length
4 - 8 m
8 - 12 m
12 - 16 m
ORDER NUMBER DOC 2326020
9 mm
10 mm
2.0 - 2.5 m³/h
2.5 - 3.0 m³/h
3.0 - 3.5 m³/h
Hose diameter
11 mm
3.0 - 3.5 m³/h
3.5 - 4.0 m³/h
4.0 - 4.5 m³/h
PEM-X1
12 mm
4.0 - 4.5 m³/h
4.5 - 5.0 m³/h
5.0 - 5.5 m³/h