Digital positioner
Table of Contents

Advertisement

Mechanical switches
Type
Size
Rating
Temp. range
NAMUR sensors
(NJ2-V3-N)
Type
Load current
Voltage range
Hysteresis
Temp. range
Proximity switches
Type
Rating
Operating time
Max voltage
Contact resistance
Temp. range
Slot NAMUR switches
(SJ2-S1N, SJ2-SN, SJ2-N)
Type
Load current
Voltage
Hysteresis
Temp
4-20 mA transmitter
Supply
Output
Resolution
Linearity full span
Output current limit
Load impedance
PMV D3 Digital Positioner
SPDT
Sub miniature
3 A/125 VAC / 2 A/30 VDC
-30°C to 80°C (–22 °F to 180 °F)
Proximity DIN EN 60947-5-6:2000
1 mA ≤ I ≤ 3 mA
8 VDC
0.2 %
–25 °C to 85 °C (–13 °F to 185 °F)
SPDT
0.4A @ 24VDC, Max 10W
Max 1.0 ms
200 VDC
0.2 Ω
-30 °C to 80 °C (–22 °F to 180 °F)
Proximity DIN EN 60947-5-6:2000
1 mA ≤ I ≤ 3 mA
8 VDC
0.2 %
–25 °C to 85 °C (–13 °F to 185 °F)
11-28 VDC
4-20 mA
0.1 %
+/–0.5 %
30 mA DC
800 Ω @ 24 VDC
47
FCD PMENIM0001-06 A5 09/16