Verify Communication Between The Director And Hafm Appliance; Director Operational States And Symbols - HP StorageWorks Director 2/140 Installation Manual

Hide thumbs Also See for StorageWorks Director 2/140:
Table of Contents

Advertisement

7. Click OK.

Verify Communication Between the Director and HAFM Appliance

Follow these steps to check director-to-server communication:
1. At the HAFM application main window (physical map or product list), inspect
Table 3: Director Operational States and Symbols
Operational—Director-to-server communication has been established,
the director is operational, and no failures are indicated.
Degraded—Director-to-server communication has been established,
but the director is operating in degraded mode and requires service.
This condition is typical if a port or redundant FRU fails. Go to
Failed—Director-to-server communication has been established, but
the director failed and requires immediate service. Go to
Status Unknown—The director status is unknown because of a network
communication failure between the director and HAFM appliance. Go
to
step
2. Right-click the Director-140 icon. A pop-up menu for the selected director
3. Check director status at the Hardware View page and complete one of the
Director 2/140 Installation Guide
the shape and color of the status symbol associated with the director icon.
Table 3
explains these symbols.
2.
displays, as shown in
In the example, the director's status is operational as indicated by the green
circle in the alert panel.
following steps:
a. If the director displays as operational (no FRU alert symbols), go to
"Configuring Feature
b. If director operation displays as degraded or a director failure is indicated
(FRU alert symbols and a yellow triangle or red diamond at the alert
panel), refer to the HP StorageWorks Director 2/140 Service Manual.
Operational State
Figure
24.
Key" on page 90.
Installing and Configuring the Director
step
2.
step
2.
Symbol
No Status
Symbol
63