Modifying Alerts; Activating Or Deactivating Alerts - HP StorageWorks Director 2/140 Installation Manual

Hide thumbs Also See for StorageWorks Director 2/140:
Table of Contents

Advertisement

Modifying Alerts

Use the following steps to modify an existing threshold alert configuration.
1. At the Hardware View page, choose Configure > Threshold Alerts. The
2. If the alert is active, click Deactivate, then choose the alert information in the
3. Click Modify. An initial Modify Threshold dialog box displays, where you
4. Choose a threshold type from the drop-down list.
5. Click Next when you are done. A Modify Threshold dialog box displays,
6. Make appropriate changes, then continue through the Modify Threshold
7. Perform either of the following steps:

Activating or Deactivating Alerts

Use the following steps to activate or deactivate existing threshold alerts. In the
active state, notifications are generated for the alert. In the inactive state,
notifications do not occur.
1. At the Hardware View page, choose Configure > Threshold Alerts. The
2. To change the state, choose the alert using the alert information in the table.
3. If the alert is active, choose Deactivate to change to the inactive state. If the
Director 2/140 Installation Guide
Configure Threshold Alerts dialog box displays.
Choose the alert that you want to modify by clicking the alert information in
the table. If the alert is active, an error message displays prompting you to
deactivate the alert.
table again.
can change the threshold type.
where you can change the % utilization, cumulative minutes for the threshold
to occur before notification, and the time interval for measuring throughput
and for alert notification.
dialog boxes, making changes as necessary, until the summary screen displays
the alert configuration.
If you need to change any parameters, click Previous or Next to display
the desired Modify Threshold dialog box.
Click Finish when you are done.
Configure Threshold Alerts dialog box displays.
The port's current state, inactive or active, is listed under the State column.
alert is inactive, choose Activate to change to the active state.
Installing and Configuring the Director
89

Advertisement

Table of Contents
loading

Table of Contents