Dealer Calibration - I50 Tridata - Raymarine i50 Depth Installation And Operation Instructions Manual

Table of Contents

Advertisement

S
pe e d
Note: The displayed distance should be very close
to the actual (measured) distance of the run.
9. If you are satisfied with the results of the first
calibration run, press the Depth and Speed
buttons at the same time for approximately 2
seconds to save the new Calibration Factor, exit
speed calibration and return to normal operation.
10. If you want to carry out a second run, press the
Speed button.
11. Follow steps 5 to 7 above again to complete a
second calibration run.
12. At the end of the return leg press the Speed
button
At this point:
• The text END alternating with the new
Calibration Factor is displayed at the top of the
page.
• The displayed distance freezes.
S
pe e d
13. To exit the Speed Run Calibration run at any time,
press and hold the Depth and Speed buttons at
the same time for approximately 4 seconds.
i50 Tridata
8.8 Dealer calibration — i50 Tridata
The dealer calibration procedures include:
• User calibration menu access On (default) and Off.
D12468-2
• Data source for speed — The data source can be
set to SOG if the display is connected to a network
containing a GPS receiver.
• Display Response for speed readings — Dictates
the rate at which the instrument display responds
to changes in speed data.
• Display Response for Depth readings — Dictates
the rate at which the instrument display responds
to changes in depth data.
• Boat show mode On and Off (default) (Boat
show mode is only available on displays set as
repeaters).
• Reset to factory defaults.
Accessing the Dealer Calibration Menu
Follow the steps below to access the Dealer
Calibration Menu.
During normal operation:
1. Press and hold the Depth and Speed buttons
at the same time for approximately 14 seconds,
until the Dealer Calibration page is displayed.
De pth
D12469-2
Setting access to the User Calibration Menu
From the Dealer Calibration page:
1. Press the Trip and Reset buttons at the same
time to display the User Calibration Access
page.
Trip
2. Use the Trip and Reset buttons to switch access
to the User Calibration Menu On (default) and
Off.
Selecting Off disables access to the User
Calibration Menu.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Speed buttons
at the same time for approximately 2 seconds.
Setting speed to SOG
Your instrument can be setup to use SOG data, if
available as the source for speed data instead of a
speed transducer.
With the speed source set to SOG the instrument
display will ignore speed readings from the
connected transducer and only display SOG
readings from a connected GPS or GNSS receiver.
From the User Calibration Menu Access page:
60 5
55
10
50
14
45
15
S
pe e d
40
20
35
25
30
Re s e t
D12481-2
D12482-2
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I50 tridataI50 speed

Table of Contents