7.8 Dealer calibration — i50 Speed
The dealer calibration procedures include:
• User calibration menu access On (default) and Off.
• Display Response for speed readings — Dictates
the rate at which the instrument display responds
to changes in speed data.
• Display Response for Velocity Made Good
(VMG) readings — Dictates the rate at which the
instrument display responds to changes in VMG
data.
• Boat show mode On and Off (default) (Boat
show mode is only available on displays set as
repeaters).
• Reset to factory defaults.
Accessing the Dealer Calibration Menu
During normal operation:
1. Press and hold the Speed and Trip buttons at the
same time for approximately 14 seconds, until
the Dealer Calibration page is displayed.
S
pe e d
Trip
Note: To exit the Dealer Calibration pages at any
time, press and hold the Speed and Trip buttons
at the same time for approximately 2 seconds.
Setting access to the User Calibration Menu
From the Dealer Calibration page:
1. Press the Timer and Reset buttons at the same
time to display the User Calibration Access
page.
Time r
Re s e t
2. Use the Timer and Reset buttons to switch
access to the User Calibration Menu
On (default) and Off.
Selecting Off disables access to the User
Calibration Menu.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Speed and Trip buttons
at the same time for approximately 2 seconds.
Setting the response delay for speed
readings
From the User Calibration Menu Access page:
1. Press the Speed button until the Speed
Response page is displayed (1 press from User
Calibration Menu Access page).
S
pe e d
i50 Speed
60 5
55
10
50
14
45
15
40
20
35
25
30
2. Use the Timer and Reset buttons to adjust the
speed response to the required level.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Speed and Trip buttons
at the same time for approximately 2 seconds.
Setting the response delay for VMG (wind)
readings
From the User Calibration Menu Access page:
1. Press the Speed button until the VMG Response
page is displayed (2 presses from User
Calibration Menu Access page).
2. Use the Timer or Reset buttons to adjust the
VMG response to the required level.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note: To exit the Dealer Calibration pages at any
D12475-2
time, press and hold the Speed and Trip buttons
at the same time for approximately 2 seconds.
Enabling and disabling Boat Show Mode
From the User Calibration Menu Access page:
1. Press the Speed button until the Boat Show
Mode page is displayed (3 presses from User
Calibration Menu Access page).
2. Use the Timer and Reset buttons to switch boat
show mode On and Off (default).
D12476-2
Selecting On will put the display into boat show
mode.
Note: Boat show mode is only suitable for
demonstration purposes and should NOT be used
whilst your vessel is in use.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Speed and Trip buttons
at the same time for approximately 2 seconds.
Resetting the display to factory defaults
From the User Calibration Menu Access page:
1. Press the Speed button until the Factory
Defaults page is displayed (4 presses from User
Calibration Menu Access page).
2. To reset the display to factory default settings: