Dealer Calibration - I50 Depth - Raymarine i50 Depth Installation And Operation Instructions Manual

Table of Contents

Advertisement

6.8 Dealer calibration — i50 Depth
Dealer Calibration enables you to set:
• User calibration menu access On (default) and Off.
• Display Response for depth readings — Dictates
the rate at which the instrument display responds
to changes in depth data.
• Boat show mode On and Off (default) (Boat
show mode is only available on displays set as
repeaters).
• Reset to factory defaults.
Accessing the Dealer Calibration Menu
During normal operation:
1. Press and hold the Depth and Alarm buttons
at the same time for approximately 14 seconds,
until the Dealer Calibration page is displayed.
De pth
Ala rm
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Alarm buttons
at the same time for approximately 2 seconds.
Setting access to the User Calibration Menu
From the Dealer Calibration page:
1. Press the Offset and Reset buttons at the same
time to display the User Calibration Access
page.
Offs e t
Re s e t
2. Use the Offset and Reset buttons to switch
access to the User Calibration Menu
On (default) and Off.
Selecting Off disables access to the User
Calibration Menu.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Alarm buttons
at the same time for approximately 2 seconds.
Setting the response delay for depth
readings
From the User Calibration Menu Access page:
1. Press the Depth button until the Depth
Response page is displayed (1 press from the
User Calibration Menu Access page).
De pth
2. Use the Offset and Reset buttons to adjust the
depth response to the required level.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
38
60 5
55
50
10
14
45
15
40
20
35
25
30
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Alarm buttons
at the same time for approximately 2 seconds.
Enabling and disabling Boat Show Mode
From the User Calibration Menu Access page:
1. Press the Depth button until the Boat Show
Mode page is displayed (2 presses from User
Calibration Menu Access page).
2. Use the Offset and Reset buttons to switch boat
show mode On and Off (default).
Selecting On will put the display into boat show
mode.
Note: Boat show mode is only suitable for
demonstration purposes and should NOT be used
whilst your vessel is in use.
D12470-2
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Alarm buttons
at the same time for approximately 2 seconds.
Resetting the display to factory defaults
From the User Calibration Menu Access page:
1. Press the Depth button until the Factory
Defaults page is displayed (3 presses from User
Calibration Menu Access page).
D12471-2
2. To reset the display to factory default settings:
i. Use the Offset or Reset buttons to change
the reset option to Yes.
ii. Press the Depth button to reset your display
to factory default settings.
3. After a reset it is recommended that you check
the data master status of the display to ensure
it is set correctly. Refer to
details.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Alarm buttons
at the same time for approximately 2 seconds.
D12472-2
De pth
De pth
6.4 Data master
D12473-2
D12474-2
for
i50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I50 tridataI50 speed

Table of Contents