Leaving Intermediate Calibration; Dealer Calibration; User Calibration On/Off - Raymarine ST60+ SPEED INSTRUMENT Owner's Handbook Manual

Hide thumbs Also See for ST60+ SPEED INSTRUMENT:
Table of Contents

Advertisement

32
• If you want to carry out a second calibration run:

Leaving Intermediate calibration

Hold down the speed and trip buttons for 2 seconds to save your settings, exit
Intermediate calibration and resume normal operation.

4.4 Dealer calibration

The Dealer calibration procedure (see
following parameters to be set:

• User calibration on/off.

• Speed response.
• VMG response.
• Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This enables
you to re-apply the factory settings if you want to reset the instrument to a known
operating condition.
To commence Dealer calibration, hold down the speed and trip buttons
together for approximately 12 seconds, to select the Dealer calibration entry
screen. Press the timer and reset buttons together, to proceed with the
calibration, then use the speed button to proceed from screen to screen as
calibration progresses.
User calibration on/off
Press the timer or reset buttons to toggle the User calibration either ON or
OFF as required. With OFF selected, User calibration and Intermediate
calibration are both disabled.
i. Press trip to start the second calibration run (see
Speed calibration
ii. Use the procedure described above in steps 4 to 7, to complete the
second run. At the end of the second run, the text END alternating
with the new calibration factor is displayed at the top of the screen.
iii. Press the speed and trip buttons together, to store the new calibra-
tion factor, exit speed calibration and return to the Instrument status
screen.
ST60+ Speed Instrument Owner's Handbook
flow chart).
Dealer calibration
sheet 2
of the
diagram) enables the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents