7.2 Intermediate calibration

Intermediate calibration allows you to:
• Check instrument software version
• * Check the instrument status (either master or
repeater)
Note: * Not available on i60 CH Wind.
+
Disp
lay
True /App
CAL
Disp
Checking the software version and
instrument status
You can check the instrument display's software
version and status by following the steps below.
Note: The i60 CH Wind instrument is a repeater
display. You cannot check or change the
instrument status of an i60 CH Wind display
From the software version page:
+
True /App
Disp
lay
CAL
Disp
During normal operation:
1. Press and hold the Display and True / App
buttons at the same time for approximately 4
seconds , until the Software Version page is
displayed.
2. Press the Display button to show the Instrument
Status page.
The instrument status is displayed (r 0 = master
and r 1 = repeater).
Note: The Software Version and Instrument Status
pages are temporary pages and will time-out
automatically after 8 seconds of inactivity.
Calibration
CAL
60 5
55
4
10
50
45
15
40
20
35
25
30
lay
CAL
60 5
55
4
10
50
45
15
40
20
35
25
30
lay

7.3 Dealer calibration

The dealer calibration procedures include:
• User calibration menu access On (default) and Off.
• Display Response for wind angle readings —
Dictates the rate at which the instrument display
responds to changes in wind angle data.
• Display Response for wind speed readings —
Dictates the rate at which the instrument display
responds to changes in wind speed data.
• Display Response for VMG readings — Dictates
the rate at which the instrument display responds
to changes in VMG data.
• * Boat show mode On and Off (default) (Boat
D12492-2
show mode is only available on displays set as
repeaters).
• Reset to factory defaults.
Note: Not available on the i60 CH wind instrument.
Accessing the Dealer Calibration Menu - i60
During normal operation:
1. Press and hold the Display and True / App
buttons at the same time for approximately 14
seconds, until the Dealer Calibration page is
displayed.
Disp
lay
Note: To exit the Dealer Calibration pages at any
D12492-2
time, press and hold the Display and True/App
buttons at the same time for approximately 2
seconds.
Setting access to the User Calibration Menu
- i60
From the Dealer Calibration page:
1. Press the VMG and Tack buttons at the same
time to display the User Calibration Menu
Access page.
VMG
2. Use the VMG or Tack buttons to switch access to
the User Calibration Menu On and Off.
• UC1 (default) — User Calibration menu
enabled
• UC0 — User Calibration menu disabled
Note: To exit the Dealer Calibration pages at any
time, press and hold the Display and True/App
buttons at the same time for approximately 2
seconds.
Setting the response delay for Wind Angle
readings
From the User Calibration Menu Access page:
CAL
60 5
55
+
50
14
10
45
15
True /App
20
40
35
25
30
CAL
CAL
Ta ck
D12493-2
D12494-2
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I60 ch wind

Table of Contents