Raymarine i50 Depth Installation And Operation Instructions Manual page 64

Table of Contents

Advertisement

1. Press the Depth button until the Speed Source
page is displayed (1 press from the User
Calibration Access Menu page).
De pth
2. Use the Trip or Reset buttons to switch the speed
data source On and Off (default).
Selecting On will display SOG reading instead of
speed transducer readings.
Setting the response delay for speed
readings
From the User Calibration Menu Access page:
1. Press the Depth button until the Speed
Response page is displayed (1 press from User
Calibration Menu Access page).
De pth
2. Use the Trip and Reset buttons to adjust the
speed response to the required level.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Speed buttons
at the same time for approximately 2 seconds.
Setting the response delay for depth
readings
From the User Calibration Menu Access page:
1. Press the Depth button until the Depth
Response page is displayed (3 presses from the
User Calibration Menu Access page).
De pth
2. Use the Trip and Reset buttons to adjust the
depth response to the required level.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Speed buttons
at the same time for approximately 2 seconds.
Enabling and disabling Boat Show Mode
From the User Calibration Menu Access page:
64
1. Press the Depth button until the Boat Show
Mode page is displayed (4 presses from User
Calibration Menu Access page).
D12483-2
2. Use the Trip or Reset buttons to switch boat
show mode On and Off (default).
Selecting On will put the display into boat show
mode.
Note: Boat show mode is only suitable for
demonstration purposes and should NOT be used
whilst your vessel is in use.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Speed buttons
at the same time for approximately 2 seconds.
Resetting the display to factory defaults
From the User Calibration Menu Access page:
D12484-2
1. Press the Depth button until the Factory
Defaults page is displayed (5 presses from User
Calibration Menu Access page).
2. To reset the display to factory default settings:
i. Use the Trip or Reset buttons to change the
reset option to Yes.
ii. Press the Depth button to reset your display
to factory default settings.
3. After a reset it is recommended that you check
the data master status of the display to ensure
it is set correctly. Refer to
details.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Depth and Speed buttons
at the same time for approximately 2 seconds.
D12485-3
De pth
De pth
8.4 Data master
D12486-2
D12487-2
for
i50