Operating; Option Selection Dip-Switch; Actuator Current Rotary Switch - Quick BTR250 User Manual

Retractable thruster
Table of Contents

Advertisement

Available languages

Available languages

OPERATING

EN

Option selection Dip-Switch

SWITCH
FUNCTION
1
Reserved (always keep off)
Informs the CAN control station that the thruster is in the bow (OFF)
2
Informs the CAN control station that the thruster is in the stern (ON)
3
Reserved (always keep off)
4
Reserved (always keep off)
FACTORY SETTING: 1 = OFF , 2 = OFF , 3 = OFF , 4 = OFF

Actuator current rotary switch

The ten selectable steps (from 0 to 9) allow you to set a percentage (see table) regarding the maximum current/load allowed for
the actuator in use.
ROTARY SWITCH POSITION
0
1
2
3
4
5
6
7
8
9
Should a setting different to the factory one be requested, carry out the following operations:
1) Turn the arrow of the rotary switch to the desired position with the board not powered.
2) When the board is powered, the percentage corresponding to the selected position will automatically be set.
If the maximum current/load is too low compared to the real operating requirements, may intervene protections against high
absorption of the actuator in closing and opening the retractable, with flashing 1 and 7 errors.
32
MAXIMUM CURRENT/LOAD %
28%
36%
44%
52%
60%
68%
76%
84%
92%
100%
DESCRIPTION
ON
1
2 3 4
ON
1
2
3 4
ON
1
2
3 4
ON
1 2
3
ON
1 2 3
RETRACTABLE THRUSTER BTR250 - IT EN - REV08B
4
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Btrh250