Pdsw', Setup The Back Panel Doorbell / Paging Switches; Ptime' Set Initial Delays And Minimum Paging Times - Zektor HDA604 User Manual

Hdmi/audio matrix switches
Table of Contents

Advertisement

Where:
preset
do_not_disturb_flag

'pDSW', Setup the back panel doorbell / paging switches

There are two voltage triggers / dry contact closures inputs on the back panel of the Zektor Switch.
These can be setup to trigger a doorbell / page.
Command format:
^pDSW switch,action,preset,time$
Response string:
^=pDSW switch,action,preset,time$
Where:
switch
action
preset
time
The 'switch' parameter refers to one of the two contact / voltage trigger inputs on the back panel.
The 'action' parameter refers to the type of switch action that triggers a page.
Active on = When the contact is closed, or a trigger voltage is present, initiate paging. Page will
last as long as the contact is closed, or trigger voltage present. The 'time' parameter is ignored.
Active off = When the contact is open, or trigger voltage is absent, initiate paging. Page will last as
long as the contact is open, or trigger voltage is absent. The 'time' parameter is ignored.
Momentary on = When the contact is closed, or a trigger voltage appears, paging will start. The
paging will last until the 'time' parameter amount of time has passed. A new page will not be trig-
gered until a the contacts are opened and re-closed, or the trigger voltage is removed and restored.
Momentary off = When the contact is opened, or a trigger voltage is removed, paging will start.
The paging will last until the 'time' parameter amount of time has passed. A new page will not be
triggered until a the contacts are closed and re-opened, or the trigger voltage is appears and then
removed.
The 'time' parameter is used by the momentary settings to indicate the amount of time the page will
last when a button is pressed, or a trigger voltage is applied. It is ignored in the 'active on' and 'active
off' modes.
Note: There is an overall timeout of two minutes for any page. For instance holding a contact closure
closed, in the 'active on' mode, will only page for two minutes. After two minutes the switch will
return to normal mode.

'pTIME' Set Initial Delays and Minimum Paging Times

When paging is triggered, you can set a fixed amount of time to wait before sources are changed, and
you can set the minimum amount of time a page will last.
Zektor Switch Serial Protocol, Version 0.16, 5/13/16
= A preset level greater than 0. A preset of 0 is ignored.
= The "Do Not Disturb" flag (0, 1, or 2).
= The switch number 1 or 2.
= The switch action that triggers a page:
0 = Disable switch.
1 = Active on (switch closed, or trigger voltage present).
2 = Active off (switch open, or trigger voltage absent).
3 = Momentary on (switch closed, or trigger voltage present).
4 = Momentary off (switch open, or trigger voltage absent).
= The paging preset level greater than 0. A preset of 0 is ignored.
= When using a momentary mode, this is how long the page is active.
Paging and Doorbell
83