Help button accessory
Program your help button before installation
and test in the desired location before mounting.
Programming
1 Follow sections 1 and 3 (Inserting batteries and
Location planning).
2 With the system in learn mode, press and hold
the red button on the help button – the LED will
light momentarily and your system will confirm
the transmission.
3 Take your system out of learn mode.
• The help button can be tested by entering learn
mode (see user guide) and activating the help
button. The siren will beep in response to the
activation. Please ensure you exit learn mode
after testing.
Using
To activate, press and hold the red button for at
least 2 seconds – LED will light momentarily and
the alarm will be activated.
To silence an alarm, press and hold down the
red button, after 10 seconds the LED will light
momentarily for a second time – alarm will be
silenced
• Please note that silencing the alarm with the
help button does not reset the system. If the
alarm is armed prior to activation, the system
will re-arm after being silenced with the help
button.
Smoke detector accessory
Programming
1 Enter the 'Devices +/-' menu and select the
'Add Device' sub menu.
2 When prompted by the control unit, press the
learn test button on the smoke detector.
3 Assign a zone number to the smoke detector.
4 Press OK to confirm.
• The smoke detector will indicate a fire by
sounding the built-in siren, lighting the LED, and
signalling the system to alarm.
• The smoke detector will produce a warning
beep and the LED will flash every 30 seconds if
the batteries are near exhaustion.
• The learn/test button can be used to test the
smoke detector. With the control unit in walk
test, press the learn/test button, the detector
will sound a two-tone confirmation and the
control unit will confirm. Please ensure that you
test smoke detectors regularly.
Downloaded from www.ukpanels.com
Remove a device
If a sensor needs to be re-programmed (for
example, to change home mode settings) or a
replacement device needs to be fitted, it first
needs to be removed from the control unit
memory.
Adding a new sensor to a used zone is
prevented until the previous sensor is deleted. To
delete a sensor, choose 'Remove Device' in the
'Device +/-' menu, all the used zones with the
sensor names are listed.
1 Use arrow keys to move the cursor to the
position where the device listed is to be
deleted.
• The list is displayed in zone number order.
2 Press OK. The selected device will be displayed
for you to confirm.
• Press a to exit if you do not want to delete
this device, the screen will return to the
previous list.
3 Press OK to delete.
List devices
To view all the devices that have already been
installed, choose 'List Devices' in the 'Device +/-'
menu, all the sensors included in the system will
be displayed.
• The list is displayed by zone number. Use arrow
keys to scroll the display. Press a to exit.
Zone already allocated
Each device can only be given one zone
number. When a sensor is added to the system
for a second time (without removing first) an error
message is displayed and then the screen will
prompt new action.