Chapter 9 Maintenance

9.8 OMA-DM

Use this screen to allow remote access to the WiMAX Device from a network
connection over OMA-DM.
Click Maintenance > Remote MGMT > OMA-DM to open this screen as shown
next.
Figure 58 OMA-DM Screen
This screen contains the following fields:
Table 47 OMA-DM
LABEL
Enable
Server URL
Server Port
Server Auth
Type
Server ID
126
DESCRIPTION
Select this to enable remote management using this service.
Enter the IP address or URL of the OMA-DM server that you intend to
use to manage this device.
Enter the port number for the IP address of the OMA-DM server set up
in the preceding field.
Select the encryption algorithm scheme used by the OMA-DM server to
communicate with client devices. If the scheme selected here does not
match the actual scheme used by the server, then server will challenge
the WiMAX Device to automatically update its settings.
None - No authentication.
Basic - Server ID and Password are encoded using a Basic Access
Authentication Code.
Digest (MD5) - Server ID and Password are encoded using a Digest
Access Authentication Code.
HMAC - Server ID and Password are encoded using a keyed Hash
Message Authentication Code.
Enter the identification code for the server. This is used by the WiMAX
Device during the communication handshake process to identify the
server.