Circumstance
Incubator doesn't operate
1
normally on the program.
Incubation starting alarm sounds
2
more than 2 times.
There is no D-Day display and
Bird icon on LCD.
3
Weight & Density loss graph is
4
not indicated well.
You connected the incubator
with computer, but the
5
connecting mark is not appear.
The temperature and humidity is
not applied normally.
6
Incubator humidity cannot meet
the setting humidity value, and
7
real-time graph draws irregularly.
Real-time temperature and
humidity graphs are not
8
indicated.
9
The computer data is different
9
from incubator data.
Incubation condition data which is input on the computer is regular conditions.
The conditions can be different from the species of birds or state of birds.
17. Troubleshooting
Take off incubator power cord and cut power supply. Put the power
cord again after 1~2min.
It can be various from connecting conditions between incubator and
PC. But if it repeats continue, try to the solution No.1
You added new( non registered) species of birds on program logo
window. It is normal, and there is no problem. You also can upgrade
firmware version later.
You did not input exact egg data or the range of data goes off the rails.
When you use the incubator first time, the computer does not connect
with computer at once, and find computer connecting port
automatically. It takes about 1~2 min. After it finds connecting port
once, it directly recognize the port later.
Without power supply, the connecting sign does not show.
This case can occur when you terminate the program or remove USB
cable before all temperature or humidity data transferred to the
incubator. When you want to terminate the program or remove USB
cable, be sure to check this sign
Short of water or humidification pad does not have enough absorbing
power because of impurity on the water. In this case, boil the
humidification pad on the water diluted with 10% of vinegar.
Even if the connection of USB cable is removed or the program is
terminated on incubation, the incubator keep the change of
temperature and humidity and transmit to PC when it connected.
During transmitting, the graph can not appear.
The incubator data can different from computer data when you started
incubation not from computer but from incubator.
Solutions
is disappeared.
36
36
36
36