E.2.2 Replacing the probe module
E.3 Regular care
E.3.1 Condensate trap
The fill level of the condensate trap can be read from the markings on the trap. A
warning message is displayed if the level in the condensate trap reaches 90% (
flashing light).
Emptying the condensate trap
The condensate consists of a weak mix of acids. Avoid contact with the skin. Make
sure that the condensate does not run over the housing.
Condensate entering the gas path.
Damage t t o t t he s s ensors a a nd f f lue g g as p p ump!
Do not empty the condensate trap while the flue gas pump is in
operation.
Placeholder:
Kondensatfalle_oeffnen.tif
Kondensatfalle_leeren.tif
1 Press the key on the top of the probe handle and
remove the probe module.
2 Fit a new probe module and engage it in place.
1 Hold the measuring instrument so that the
condensate outlet points up.
2 Open the condensate outlet of the condensate
trap: Push out approx. 7 mm to the stop).
3 Let the condensate run out into a sink .
4 Mop up any remaining drops on the condensate
outlet using a cloth.
5 Close the condensate outlet.
The condensate outlet must be completely closed
(marking), otherwise measuring errors could occur
if external air gets in.