Symbol Definitions; Command And Response Table For Sis Commands - Extron electronics FOX T USB User Manual

Extender plus fiber optic extenders for usb peripherals
Table of Contents

Advertisement

Symbol Definitions

]
} or
E or
X!
X@
NOTE:

Command and Response Table for SIS Commands

ASCII Command
Command
(Host to Unit)
Information Requests
Request part number
N
Query firmware version
Q
Example:
Q
Query version and build
*Q
Reset
Reset
E
Absolute reset
E
Peripheral Emulation (Transmitter Only)
NOTE:
These commands can be issued only to the transmitter.
Set peripheral emulation
E
View peripheral
E
emulation
= CR/LF (carriage return and line feed) (hex
= Soft carriage return (no line feed)
¦
= Space
= Escape key (hex
W
1B
= On and off (enable and disable)
= Off or disabled
0
= On or enabled
1
= Extender unit part number:
Transmitter: 60-1471-12
Receiver: 60-1471-13
Unless otherwise indicated, commands are not case sensitive.
Response
(Unit to Host)
X@ ]
n.nn
1.01
n.nn.nnnn
}
ZXXX
Zpx
}
ZQQQ
Zpq
X!
}
E
USBC
Usbc E
}
X! ]
E USBC
FOX T/R USB Extender Plus • Remote Configuration and Control
0D 0A
)
Additional Description
Show the extender part number
X@
For
:
Transmitter, MM: 60-1474-11
Transmitter, SM: 60-1474-12
Receiver, MM: 60-1474-21
Receiver, SM: 60-1474-22
]
Show firmware version, expressed to the
second decimal place.
]
The unit firmware version is 1.01.
]
Show firmware version and build number.
]
Reset the extender to factory default
values.
]
Reset all unit values.
X! ]
Set peripheral emulation for the FOX T/R
USB Extender Plus to
0 = disabled
1 = enabled (default)
)
X@
.
X!
X!
. For
:
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fox r usb