6270 Installation and Setup Guide
Diagnostics
N
Keypad Emulation
N

Compatibility

The below listing identifies the alarm systems that the 6270 can
interface with, the maximum number of 6270s that can be used with
each system, and the minimum alarm panel software revision level
for compatibility.
MAXIMUM NUMBER
ALARM SYSTEM
VISTA-20PS
VISTA-128BP
VISTA-128FBP
VISTA-250BP
VISTA-250FBP
FA168CPS
FA1660C
FA1700C
On all panels except the VISTA-20PS and FA168CPS, you may obtain
the software revision level of the alarm panel by entering the program
mode and then entering #92 on the keypad. The second line of the
keypad displays the software revision level (without the decimal point).

ECP Error

The message "ECP Error" will be displayed at the top of the screen (except for
the Home screen) when the 6270 cannot communicate with the alarm panel.
This may be caused by and incorrect ECP address in the 6270 or because AUI
type devices have not been enabled in the panel. While this message is being
displayed, you must use the 6270 default code of "4140" any time the 6270
requests an authorized code.
1–2
MINIMUM SOFTWARE
OF 6270s
2
3
3
3
1
2
3
1
REVISION LEVEL
All Levels
2.4
1.6
2.4
1.5
All Levels
2.4
1.5