ADEMCO 6128WL Installation Instructions Manual
ADEMCO 6128WL Installation Instructions Manual

ADEMCO 6128WL Installation Instructions Manual

Wireless keypad

Advertisement

Quick Links

General Information

The 6128WL Keypad/Receiver is a combination unit. It replaces a 6128 Fixed Addressable Keypad and a 5881/5882M
RF Receiver. The 6128WL may be used on any QED or hardwired only control panel that supports the 6128 Keypad
(i.e., VISTA-10SE, VISTA-20SE, VISTA-40, VISTA-50P, 4110DL, 4110XM, 4140XMP, Vista-20HWSE).

Wireless Setup Considerations

There are 2 major elements involved in setting up the 6128WL. They are:
1.
Wireless Keys (may be used as either System keys or Local keys).
2.
RF Receiver (may be used as either a System receiver or a Local receiver).
Understanding how these 2 elements are programmed is important for using the 6128WL. An application guide
following the explanations outlines the programming of each element for various installations.
1.

Wireless Keys:

These are button-type transmitters (i.e., 5804).
They may be set up as System keys or Local
keys.
System keys are enrolled into the QED
supported control panel.
Local keys are enrolled directly into the
6128WL (a maximum of 8) and are not
supervised for low battery conditions.
Local keys DO NOT occupy any zones
supported by the control panel.
2.

RF Receiver:

The built-in 5881M/5882M Receiver may be
used on a QED supported control as either a
System receiver or a Local receiver.
A
System
receiver
transmitters programmed into the control
panel to the control panel.
A System receiver passes signals from RF
keypads to the control panel as regular 5800
signal data.
When used as a System receiver, it supports a
maximum of 16 transmitters.
The receiver and wireless keys have a nominal
range of 200'.
INSTALLATION INSTRUCTIONS
For use with QED and hardwired control panels ONLY!
passes
signals
The 6128WL is shipped with default settings
for the functions of the wireless keys. See the
Programming Local Wireless Keys section for
the default settings.
Enrolling the keys directly into the 6128WL would
be necessary only in the following circumstances:
When using more than the maximum number
of transmitters supported by the control panel.
When used with a hardwired control panel.
In all other cases, use wireless keys as System keys
(enroll them into the QED supported control panel).
Programming the receiver as Local would be
necessary only in the following circumstances:
When using more
transmitters AND the number of receivers
from
supported by the control panel.
When used with a hardwired control panel.
NOTES:
a) When used as a System receiver, do not exceed
the number of receivers the control panel
supports.
b) When used as a System receiver, wireless keys
may still be used as Local keys.
K3129-5 10/98
6128WL
Keypad/Receiver
than
the
number of

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6128WL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADEMCO 6128WL

  • Page 1: General Information

    The 6128WL Keypad/Receiver is a combination unit. It replaces a 6128 Fixed Addressable Keypad and a 5881/5882M RF Receiver. The 6128WL may be used on any QED or hardwired only control panel that supports the 6128 Keypad (i.e., VISTA-10SE, VISTA-20SE, VISTA-40, VISTA-50P, 4110DL, 4110XM, 4140XMP, Vista-20HWSE).
  • Page 2 2. The ARMED and READY LEDs will flicker while the unit is powered. This is most noticeable while the LEDs are in the off state (disarmed and not ready). This is normal and will not affect any operation of the 6128WL.
  • Page 3 Entering Program Mode Press the 1 and 3 keys simultaneously for a few seconds within 30 seconds of applying power to the 6128WL. The keypad will beep 3 times, and 2 dashes and 2 zeroes will flash alternately in the upper left-hand corner of the display. If any other numbers or letters are flashing in the display, press the [ ] key.
  • Page 4 Programming this section is necessary only if you plan to use wireless keys beyond the QED control panel’s capacity, or on a system that does not support 5800 Series wireless. Refer to the 6128WL Application Guide on page 2 for installations that require these settings.
  • Page 5 Example A 4204 relay on a Vista-40 is programmed to turn on when a Code + # + 71 is entered at a keypad. Program a loop of a wireless key with an entry of # + 71. When the button of the wireless key is pressed, the 6128WL sends to the control the 4-digit code (sub-option 2) + # + 71 and the 4204 relay turns on.
  • Page 6: Specifications

    1 & 3 keys at the same time, then press [1] and verify the keypad address. Defaulting the 6128WL The 6128WL is shipped with a set of pre-programmed default values. The installer, to suit specific needs, can change these default values. To restore the 6128WL’s default values, perform the following procedure: Enter the program mode.
  • Page 7 24 months from the date stamp control on the product or, for products not having an Ademco date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply.
  • Page 8 165 Eileen Way, Syosset, NY 11791 Copyright © 1998 PITTWAY CORPORATION ¬.+l K3129-5 10/98...

Table of Contents