User Calibration - Adam Equipment UG119 User Manual

Muw health and fitness scale
Table of Contents

Advertisement

Available languages

Available languages

EN
7.0

USER CALIBRATION

Switch on the scale and whilst the display counts down press the [Clear]
1)
key.
2) The display will show kg or lb, press [Print] to select the unit of weight
being used for the calibration and then [Zero] to confirm.
3) The display will show CAL XX (XX being the last calibration weight to be
used).
4) Press the [Print] key to change the value if required and [Zero] to
confirm.
5) The display will show the Zero A-D which should be stable.
6) Press the [Zero] key to confirm the Zero point and the display will show
LOd XX (XX being the calibration weight value to be loaded onto the top
pan).
7) Load the top pan with the calibration weight and press the [Zero] key.
8) The display will show "PASS" for a successful calibration and return to
normal weighing displaying the calibration weight value correctly.
9) Remove the weight from the pan and the scale will return to Zero.
*A print out with date and time can be issued following every calibration.
If an error code was displayed when calibrating please see the error code
table in section 9.1
© Adam Equipment Company 2012
15
700660229revA-Jul12