Adam Equipment WBW 15M User Manual

Adam equipment wbw series weighing scales

Advertisement

Adam Equipment
WBW SERIES
WBW..M EC and WBW..aM NTEP
Type Approved
(P.N. 303669031, Revision E3, November 2011)
© Adam Equipment Company 2011

Advertisement

Table of Contents
loading

Summary of Contents for Adam Equipment WBW 15M

  • Page 1 Adam Equipment WBW SERIES WBW..M EC and WBW..aM NTEP Type Approved (P.N. 303669031, Revision E3, November 2011) © Adam Equipment Company 2011...
  • Page 2 © Adam Equipment Company 2011...
  • Page 3: Table Of Contents

    12.4 WBW SERIES , NOT APPROVED ..............15 13.0 PARAMETER SETTING ..................17 13.1 CHECK WEIGHING PARAMETERS ...............17 13.2 SCALE PARAMETERS ...................18 14.0 ERROR CODES .....................19 15.0 REPLACEMENT PARTS AND ACCESSORIES.............20 16.0 SERVICE INFORMATION ..................20 17.0 WARRANTY INFORMATION .................21 © Adam Equipment Company 2011...
  • Page 4 © Adam Equipment Company 2011...
  • Page 5: Introduction

    (LCD) supplied with a backlight. The scales can be supplied with an optional rear display. • The scales include automatic zero tracking, audible alarm for pre- set weights and semi-automatic tare. © Adam Equipment Company 2011...
  • Page 6: Specifications

    144 oz 288 oz 560 oz Readability 0.01 oz 0.02 oz 0.05 oz 0.1 oz Repeatability (S.D.) 0.01 oz 0.02 oz 0.05 oz 0.1 oz Linearity (±) 0.02 oz 0.04 oz 0.1 oz 0.2 oz © Adam Equipment Company 2011...
  • Page 7 If the seals are broken or tampered with, the scale needs to be re-verified by an authorised certification body and re-sealed, before it is used legally. Contact your local metrology standards office for further assistance. © Adam Equipment Company 2011...
  • Page 8: Installation

    Avoid air movement such as from fans or opening doors. Do not place near open windows or air-conditioning vents. • Keep the scales clean. Do not stack material on the scales when they are not in use. © Adam Equipment Company 2011...
  • Page 9: Setting Up

    • At the end of the self-test it will display zero weight, if the zero condition has been achieved and the weighing unit that was in use last. A stable and zero symbol indicators are also displayed. © Adam Equipment Company 2011...
  • Page 10: Keypad

    To set a value when required, use the keys as given below- - [Limit] key to increase the flashing digit, - [Unit] key to move to the next digit and - [Tare] key to accept the value © Adam Equipment Company 2011...
  • Page 11: Display

    Above the LCD to the left, there are three LED’s that indicates when the weight is below, within or over the pre-set limits during check weighing. Weight Below the low limit Within the limits Green Above the high limit Amber © Adam Equipment Company 2011...
  • Page 12: Battery Operation

    9.0 AUTO POWER OFF The auto power off can be set by the user to disable the feature or to a pre- set time interval. See setting of the parameter “S3 AoF “ in section 13.2. © Adam Equipment Company 2011...
  • Page 13: Operations

    • As a product is added only the weight of the product will be shown. The scale could be tared a second time if another type of product was to be added to the first one. Again only the weight that is added after taring will be displayed. © Adam Equipment Company 2011...
  • Page 14: Weighing

    13.1). The LCD display will indicate whenever the weight is within or exceeds the limits by showing ‘OK’, ‘HI’ or ‘LO’. Mass on the balance is above the high limit Mass is between the limits Mass is below the low limit © Adam Equipment Company 2011...
  • Page 15: Limits Stored In Memory

    If the scale is turned on again, the limits and the weighing unit will be active. 11.0 RS-232 INTERFACE The RS-232 is not available in WBW scales. © Adam Equipment Company 2011...
  • Page 16: Calibration

    NOTE: IF THIS SEAL IS BROKEN THE SCALE MUST BE RE-SEALED BY THE RELEVANT AUTHORITIES USING EITHER THE LEAD WIRE SEAL OR AN ACCEPTABLE SEAL BETWEEN THE COVER AND THE BASE. © Adam Equipment Company 2011...
  • Page 17: Calibration Counter

    If the mass is different from the displayed value, enter the value of the mass in whole numbers using the numeric entry method (see section 4.1). The kg or the lb symbol will be on to show the active unit. © Adam Equipment Company 2011...
  • Page 18 NOTE: If an error message “FAIL H” or “FAIL L” is shown during calibration, re- check the calibration and repeat, if necessary. If the error cannot be corrected contact your dealer or Adam Equipment for advice. © Adam Equipment Company 2011...
  • Page 19: Parameter Setting

    Check weighing password, manually. If the old parameter is “0000” enter the new password twice when “ _ _ _ P2 _ _ _ _ “ & “ ” are displayed. When complete, it will display © Adam Equipment Company 2011...
  • Page 20: Scale Parameters

    SLP 1 SLP 5 SLP 10 S4 diS Display all weights or only when stable StAb Filter setting to slow, normal or fast S5 Fi SLow FASt Auto Zero range, 0.5d S6 AZr 0.5d 1.0d 1.5d © Adam Equipment Company 2011...
  • Page 21: Error Codes

    Calibration error Improper calibration (should be within +10% FAIL H of the factory calibration). The old calibration FAIL L data will be retained until the calibration process is complete. © Adam Equipment Company 2011...
  • Page 22: Replacement Parts And Accessories

    15.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of such items is as follows- • Power Supply Module • Replacement Battery • Stainless Steel Pan •...
  • Page 23: Warranty Information

    17.0 WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company.
  • Page 24 Adam Equipment ADAM EQUIPMENT, BOND AVENUE, DENBIGH EAST INDUSTRIAL ESTATE, MILTON KEYNES, MK1 1SW, U.K. Tel: (01908) 274545 Fax: (01908) 641339 Intl Tel: -44 1908 -274545 Intl Fax: -44 1908 641339 E-Mail Address: info@Adamequipment.co.uk Declaration of Conformity Verklaring van overeenstemming Konformitätserklärung...
  • Page 25 APPENDIX © Adam Equipment Company 2011...
  • Page 26 © Adam Equipment Company 2011...
  • Page 27 Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. WEEE COMPLIANCE...
  • Page 28 For a complete listing of all Adam products visit our website at www.adamequipment.com © Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment.

Table of Contents