Advertisement

Quick Links

IP BOLD - Door Phone
IP BOLD – Tx
IP BOLD – TxC
IP BOLD – TKx
IP BOLD - TKxC
Installation and operating instructions

Advertisement

Table of Contents
loading

Summary of Contents for Valcom IP bold series

  • Page 1 IP BOLD - Door Phone IP BOLD – Tx IP BOLD – TxC IP BOLD – TKx IP BOLD - TKxC Installation and operating instructions...
  • Page 3 Welcome Congratulation to purchase modern VOIP door entry system “Vo IP D ” IP BOLD. This door entry widely satisfy your needs for BOLD hone communication to visitors of your company, homes, schools etc… Simply VoIP means “Voice over Internet Protocol” – this door entry is connectable to IP network and allows 2 ways of calling.
  • Page 4: Table Of Contents

    Contents BASIC DESCRIPTION ..................6 ...................... 6 EATURES ..................7 SED TERMINOLOGY ................8 ODULES COMPOSITION IP BOLD ................10 CONNECTION 1.4.1 IP BOLD basic board ................10 1.4.2 Relays connection ................... 13 1.4.3 PoE ......................17 1.4.4 Usage of door contacts ................17 IP BOLD ................
  • Page 5 3.4.4 Setting SNMP ..................48 3.4.5 Time profiles ................... 49 3.4.6 Date and time setting ................51 3.4.7 E-mail ..................... 52 ..................54 XTENDED SETTING 3.5.1 Door entry ....................54 3.5.2 Audio setting ................... 57 3.5.3 Audio codecs ................... 59 3.5.4 Video setting ...................
  • Page 6: Basic Description

    Basic description 1.1 Features  audio is full duplex with ECHO cancellation  phone book for 999 subscribers (when keypad is used)  every subscriber has more phone numbers with progressive simultaneous calling  Email sending when is unreachable including attachment with pictures ...
  • Page 7: Used Terminology

    1.2 Used terminology  Ethernet is technology which is used to build up local networks (LAN)  LAN - Local Area Network (local network) mark PC network which cover small geographical area (for example homes, office, etc…).  10Base-T As transmission medium use twisted twoline cable with rate 10 Mbit/s.
  • Page 8: Modules Composition

    1.3 Modules composition Door entry IP BOLD includes modern technology, timeless design and user friendly installation and service. Door entry IP BOLD is equiped by 2 relays and PoE feeding. Basic models are different by using of keypad or full colour wideangle camera. Version with camera has integrated fully colour wideangle camera on basic board.
  • Page 9 IP BOLD-TK1C IP BOLD-TK4C IP BOLD - installation and operating instructions...
  • Page 10: Ip Bold Connection

    1.4 IP BOLD connection The IP BOLD includes basic board differently equipped. To the basic board is possible connect 1 or 2 button boards. Further is possible connect keypad in version TK. 1.4.1 IP BOLD basic board The basic board is the same for all models of IP BOLD door entry. The difference is just camera module ( with or without).
  • Page 11 9. The LED to control network activity, green = connection 100M LAN, yellow = data transmission on the LAN 10. Connector to Conner keypad module 11. DIP switch – allways ON (servis purpose only) – OFF, hen is ON during start then default IP adress 192.168.1.250 is setup 3,4 –...
  • Page 12 IP BOLD - installation and operating instructions...
  • Page 13: Relays Connection

    1.4.2 Relays connection Relay contacts connection (3) and (4) is on the picture. Marking "NO" menas in stand by open contact, "COM" means shared output (middle) and "NC" means in stand by closed contact. Contacts of both relays are mutually galvanically isolated as same as isolated from othe IP Bold components.
  • Page 14 Possibilities of relays connection are at following pictures: IP BOLD - installation and operating instructions...
  • Page 15 IP BOLD - installation and operating instructions...
  • Page 16 1. Standard electrical lock connection. This connection is used most often. One shared power supply feeding door entry IP BOLD and both electrical loch. Current loading of PSU depends mainly on used el. Locks. Standard el. Lock has current consumption 0,6A – 1,0A. As next you have to consider posibility of both relays activation simultaneously.
  • Page 17: Poe

    1.4.3 PoE The IP BOLD is equiped by circuit for powering via UTP cable – PoE. When you have IP switch with PoE, or you have PoE PSU (box of adapter size inserted into UTP cable input – according directive IEEE802.3af) then you dont need extra 12V PSU for door entry powering.
  • Page 18: Installation Of Ip Bold

    1.5 Installation of IP BOLD 1.5.1 Wall mounting installation Installation place To reach good video quality the camera must not point directly to • sun lighting • strong light sources • light orstrongly reflective walls Installation height Installation height of outdoor video station should be selected according camera scan range (via picture).
  • Page 19: Montage Dimension

    1.5.2 Montage dimension IP BOLD - installation and operating instructions...
  • Page 20: Open And Close Of Cover

    1.5.3 Open and close of cover Cover opening Bottom lath is connected to alu profile by 2 internal sixedge screws (1) Screw up to middle way by enclosed key those screws (2) turn bottom lath to left without its complete taking (3) slide out name card plexi Cover closing Slide name plexi under lath...
  • Page 21: Name Cards Changing

    1.5.4 Name cards changing Name cards writing Templates you will find on our website www.alphatech.cz 1. Write desired names into template. 2. Print out name cards to special foil* and cut them of. 3. Release pockets on external edge of name plexi by delivered plastic board. 4.
  • Page 22: Service Of Ip Bold

    Service of IP BOLD 2.1 Signalling overview The door entry IP BOLD signalling acustically stages which occurs during operation. Further signalling is by 2 colour LED (placed right under black plexi). Acustical signalling for each status mentioned in bellow table might be switched off or might be used default tones “beeping”...
  • Page 23: Button Press - Code Lock

    1. Phone book position for selected button must be permitted 2. Must be fill min. 1 from 5 phone numbers (or IP adresses in P2P mode) 3. At filled phone number is active time plan in appropriate time or no plan is selected.
  • Page 24: Call

    2.2.4 Call Door entry IP BOLD has adaptive ECHO canceller. The Echo dissapear usually within first 5 seconds of call. The call is then full duplex. The end of call happen: Called party hang up Call duration time is over (when is setup) By button press(hen is setup) Visitor inside building By person inside building is person who is in communication with door...
  • Page 25: Video

    2.4 Video At models with camera is possible received video as follow: - IP phone with LCD display - PC – WEB browser - PC with programm UDVguard (www.alphatech.cz) - PC with general programm for video watching (for example VLC) - Android device (smart phone, tablet) UDVguard (Google Play) - Apple device (smart phone, tablet) UDVguard (iTunes) Video formats: JPG, MJPG, H.263, H.264...
  • Page 26: Parametres Programming

    Parametres programming Parametres programming is performed by ordinary WEB browser. (Caution! version of IE V7 and lower are not supported). 3.1 WEB interface access For successful display of WEB interface of IP BOLD door entry we go through some details. Field length - names, titles, codes, passwords have fix length 40 characters.
  • Page 27: Login

    Then you can setup parameters of door entry including IP address and after restart of IP BOLD door entry you can login to door entry WEB page on new IP adress. 3.1.2 Login In your WEB browser write IP adress of IP BOLD door entry in default it is 192.168.1.250.
  • Page 28: Current Status

    3.2 Current status Current status display basic data about IP BOLD door entry status. It display Firmware version,door entry model, options connection (camera, keypad), SD card, MAC adresses, current time, network setting, door entry mode (P2P or SIP server), registration status and small calls statistic. IP BOLD - installation and operating instructions...
  • Page 29: Language Settings

    3.2.1 Language settings After language selection please don’t forget click on „Save changes“. On the right top corner is display flag of current used language in whole WEB interface. After click on flag accessible language will be display. After language selection please don’t forget click on „Save changes“...
  • Page 30: Ip Network Setting

    3.3 IP network setting 3.3.1 IP Network setting Network settings you find in menu „Network setting“. You can select using of fix IP adress or dynamically assigned by using DHCP. Configuration of fix IP adress: After performing of required changes please don’t forget click on „Save and restart“.
  • Page 31 Internet gateway – Router IP adress (Internet connection) DNS server 1 and 2 – IP adresses of primary and secondary domain server NAT address - used for network traffic through the router (modifies transcription of the original or destination IP address) DHCP configuration: After performing of required changes please don’t forget click on „Save and restart“.
  • Page 32 Important: if you use DHCP setting then DHCP assign IP address to door entry automatically and network administrator will assure your current IP address to be able watch video in WEB browser. Therefore this dynamically assigned IP address might be changed due for example power failure we recommend use dooe entry IP BOLD with fix IP adress.
  • Page 33: Sip Setting

    3.3.2 SIP setting The door entry IP BOLD might operates in 2 basic modes. It is either SIP server – door entry registration is performed to SIP server and then you call to phone numbers assigned by SIP server or Peer to Peer (P2P) – door entry call exact IP adress and SIP server services can´t be used.
  • Page 34 name - unit name in SIP protocol (usually line number or name without diacritics) Auth.ID - name for SIP server registration Heslo - password for SIP server registration Send registration – when registration is necessary (mostly yes) then this parametr must be used Registration server - IP adress or server name of registration server (in most systems and installations is enough to insert IP adress).
  • Page 35 Peer to Peer mode (P2P) After performing of changes please don’t forget click on „Save changes“. title - name – name by which is device presented in network (for example will display as door entry name in programms UDV panel, UDVguard) Name - unit name in SIP protocol (usually line number), it is recommended to keep filled.
  • Page 36 RTP. After sends data to same adress:port from which message arrived. It is trick used for bridging NAT. In active mode - P2P is possible to operate device, which require for their function registration at the SIP server. This option will use new SIP phones, which generally do not support P2P mode, as well as applications for iOS - Apple.
  • Page 37: Web Server

    3.3.3 WEB server After performing of changes please don’t forget click on „Save and restart“. WEB interface TCP port - posibility of chase usuall TCP port 80 to other (security reasons) New access password / password confirmation – inserting of new access password (instead default password 1234) –...
  • Page 38 Home page video – Video ON/OFF on home page of WEB interface (mainly from security reasons. When video is OFF it is accessable after login with password only). Video protection by password – further protection is secure access by password http://ipaddress/video.jpeg (camera picture).
  • Page 39: Basic Setting

    3.4 Basic setting In this part are setup user and most often changed parametres. 3.4.1 Phone book After performing of changes please don’t forget click on „Save“. IP BOLD - installation and operating instructions...
  • Page 40 The phone book contents 999 subscribers. For first 99 subscribers agree subscriber number with button number. In this version of door entry – IP BOLD is max = 4 button. Therefore first 4 subscribers are most important. The door entry IP Bold is equipped by automatic detection of connected devices.
  • Page 41 Time plan – when is not selected then 4th number is allways active. Usage of 4th phone number might be limited by time plan Calling - allows create groups – via follow. 5th phone number- is phone number which is dial as fifth (when is used progressive dial mode).
  • Page 42: Relays

    3.4.2 Relays After performing of changes please don’t forget click on „Save“. In relays setting are accessible 4 relays. The relays 1 and 2 is output of relays contacts directly in IP BOLD door entry. Next 2 relays (3 and 4) is possible use for remote relays (IP relays via follow) or as virtual relay usefull for synchronization to allows creation of more difficult functions of relays.
  • Page 43 Permitted – relay function might be eliminated. Due this will be eliminated synchronization signal for other relays. Meaning is for example when you want temporarily prevent certain door opening. Then instead of all codes cancellation and their repeated programming simply prohibit this relay.
  • Page 44 and synchronization delay 7 sec. Codes for relay 1 closing are 55 and 56. The relay 4 we setup as monostable, closing time 1 sec, closing code 55. By synchronization you can create different closing combination. Synchronization delay – time between synchronization start and its evaluation.
  • Page 45 Security code for output – relay output is close/open in default. This static status is dangerous in case of unauthorised enter for example by door entry demaged and short circuit wires of power supply and electrical lock. Defence is using module COSW which you connect to electrical lock wires –...
  • Page 46: Door Sensors

    3.4.3 Door sensors Door sensors are special functions of door entry IP BOLD which is optional. It is HW option which is different according button number of each model – inputs for door sensors. There is created information in the system about close/open the door.
  • Page 47 Sensor 1 / 2 permit or prohibit – by permission is activated transmission of Inko about open / close the door. This Info is display ether on this page – Now is – or on home page with video(under video frame will be display frames with this Info.
  • Page 48: Setting Snmp

    3.4.4 Setting SNMP Remote management – SNMP is internet protokol designed for network management. It allows progressive data collection for network management purposes and its following evaluation. After performing of changes please don’t forget click on „Save“. SNMP enable – by mark you activate remote management (SNMP) Comunity –...
  • Page 49: Time Profiles

    SNMP communication. OID is created by number sequence separand by dot. Every dot represent exact level of tree structure into which are OID maped. The numeral identification in range of each undertree is not Unixe that is why OID is sent allways as whole unit. 3.4.5 Time profiles After performing of changes please don’t forget click on „Save“.
  • Page 50 In time profiles setting is available 10 profiles. Profile selection is perform by click in top highlighted row – similiary as in phone book. Profile name – for easy orientation you can named every profile. Period setting table – profile is active when current time match with setup periods.
  • Page 51: Date And Time Setting

    3.4.6 Date and time setting After performing of changes please don’t forget click on „Save“. Time zone – selection of installation time zone Time server – IP adress or domain name of NTP server. When you dont know then by inserted * will IP BOLD find NTP server automatically according own selection.
  • Page 52: E-Mail

    3.4.7 E-mail When you want inform subscriber about missed calls from door entry you can setup IP BOLD to sent out email after every missed call. You can setup own subject and text of email. When you have door entry with camera you can automatically add to email one or more pictures from camera.
  • Page 53 Enable SMTP service – it activates email sending SMTP server (adress) - SMTP server adress where emails will be sent Port SMTP server – adjust in case of none standard SMTP server setting only. SMTP port is setup usually on value 25 Registration name –...
  • Page 54: Extended Setting

    3.5 Extended setting This part is designed for system setting which are done once during installation or when are problems with device kompatibility. 3.5.1 Door entry After performing of changes please don’t forget click on „Save“. IP BOLD - installation and operating instructions...
  • Page 55 Ringing time – time for which is ringing. When is setup more numbers as same as progressive ringing then after this time ringing is ended on first phone number (IP adress in P2P) and starts ringing on second. It is time until which subscriber must pick up. When is not next number to call then email is sent either to email adress mentioned in phone book or to default email (E-mail setting).Setting range is 5 to 300sec (6min.) caution: it might happen that ringing time will not be...
  • Page 56 pressed button on door entry (1-999). Direct phone numbers dial means that you dial numbers by keypad as on ordinary phone. When you have in numbers dial space longer than maximal number inserting time then door entry calls. When you want in mode P2P call to IP adress then „.”...
  • Page 57: Audio Setting

    3.5.2 Audio setting After performing of changes please don’t forget click on „Save“. Speaker loudness + microphone sensitivity – amplification setting ECHO limiter – it is designed for Echo cancellation which is created by distortion of loud signal.During standard door entry call is working automatic adaptive echo canceller which cancel the echo after cca 3 seconds of talk and call is full duplex.
  • Page 58 signals coming from phone to speaker of door entry are distorted and automatic echo canceller cant process them. This level you setup (in %). How much should be reduced signal returning through microphone input is adjusted by reducing. Delay of returning signal is adjustable by samples amount.
  • Page 59: Audio Codecs

    3.5.3 Audio codecs After performing of changes please don’t forget click on „Save“. Priority – setting of codecs priority for usage. Some audio codecs requires payable license (for example G729) – codec permission you perform in Servis – license management. Jitter compenzation - jitter means fluctuation of packet delay during network running IP BOLD...
  • Page 60: Video Setting

    3.5.4 Video setting After performing of changes please don’t forget click on „Save“. Image size– image size selection. Stream H.263 knows just CIF resolution (352x288) so bigger image is cut and smaller image is framed IP BOLD - installation and operating instructions...
  • Page 61: Video Watching (Popup Programm)

    Image number per second – this setting concern mainly image transmission to WEB browser. For H.263(4) is flow control flexibly according processor and network workload and it is in range 5-15 pictures/sec. Further setting is standard image parametres petting and reset is immediatelly visible in Windows screen.
  • Page 62: Video Codecs

    3.5.6 Video codecs After changes performing please don’t forget click on „Save“. Priority – setting of codecs priority for usage . Compatibility – Due some of VOIP phones producers specialities you have to use in certain cases extra setting: Polycom – phones Polycom Yealink –...
  • Page 63: Streaming

    3.5.7 Streaming After changes performing please don’t forget click on „Save“. RTSP server – permitted / prohibited to provide video (H.263 and H264) by door entry IP BOLD (server) protocol RTSP on port 554. To receive such video you need some standard stream video players (IP TV or for example Grandstream, MPlayer, VLC etc…).
  • Page 64 Permitted IP adress – when is not filled up then video might be watch by anybody. When is filled then video is limited just for this IP adress Transmitted media – selection of what will be transmitted from RTSP server: - video - audio - video and audio...
  • Page 65: Service

    3.6 Service This part contents service functions. 3.6.1 Restart By click on „Restart“ button you make door entry reset. IP BOLD - installation and operating instructions...
  • Page 66: Configuration

    3.6.2 Configuration The door entry IP BOLD allows saving of current setting to PC or other repositury. From this saved file you can later restore this setting in a few levels – for example phone book only. It helps for example during installation of door entry in more entries to the building.
  • Page 67 Configuration loading – by click to empty button will be offered file selection. Further is necessary select if phone book, network setting, SIP and other parametres have to be loaded. By click to „Make” button is loaded door entry petting from the file. Default (factory) setting –...
  • Page 68: Language And Style

    3.6.3 Language and style file Style import – by click to empty button select the file and by click to „Make” is style file (symbols and colours setting) loaded. Clean languages – it allows erase all added languages except factory languages En+Cs (mark and click on perform) File language import –...
  • Page 69: Style And Language Preparation

    File language export – after click on „Make” button will be performed language file export of just selected language 3.6.4 Style and language preparation Style file is HTML file. WEBpage formating is included in this file. Requirement is basic knowledge of HTML language. For transparent editing we recommend use programm PSPad, symbols sada must be UTF8.
  • Page 70: Firmware Upgrade

    3.6.5 Firmware upgrade FW version – display present firmware version in door entry IP BOLD Firmware file – by click to empty field select file with firmware (for example apt.firmware it is not file *.zip, but already unzip file – on website are firmware files packed to archive *.zip) In Windows is display proces so firmware upgrade.
  • Page 71: Logfile

    interface for repeating of firmware upgrade. After do not forget move back DIP switch 2 to position OFF. After firmware upgrade make restart of door entry IP BOLD. 3.6.6 Logfile IP BOLD - installation and operating instructions...
  • Page 72 Start enhanced log – it is OFF in default to save processor efficiency. When you switch it ON then are save into internal memory detail information about door entry operation. It is very helpfull to solve different problems ( compatibility etc..). Download log file –...
  • Page 73: License

    3.6.7 License This page allows extend door entry features about payable functions via licenses.For example audio codec G729. After payment you receive license number by email License validity shows if license is working correctly. The license code is connected to MAC number of door entry. IP BOLD - installation and operating instructions...
  • Page 74: Sound Files

    3.6.8 Sound files This page is designed for recording own (user) sounds signalling. By click on „Play“ will be played currently active sound file (selection is permormed on page „Audio setting“ eventually sound of relay closing on page „Relays“). Attention files are recorded on a microSD card! Audio files: WAV –...
  • Page 75: Technical Parametres

    Technical parametres 4.1 Electrical parametres Parametr Value conditions Interface Ethernet 10BaseT, 100BaseTx VoIP protocol SIP 2.0 defined RFC3261 Default IP address 192.168.1.250 G.711u, G.711a, G.726-32b, GSM, G722, Audio G729 (optional) 300Hz – 3400 Hz Band range Echo supression automatical série JPEG, MJPG, stream H.263, H.264 Video Resolution Max.
  • Page 76: Video Parametres

    Video parametres Video formats: JPG, MJPG, H.263, H.264 Video for WEB: Internet Explorer, Mozilla, Opera, Firefox… - (set of JPG pictures - Port 80) it is used repeated http request „IPadresa/video.jpg“ programm PopUp (UDVguard) - (MJPEG stream - Port 80) is used http request „IPadresa/video.mjpg“...
  • Page 78 Telnet)  damages caused during product transport to customer and from supplier Producer: Dealer: Valcom Support Services On Call House, 14 Brookhill Close, Standedge Business Park, Diggle, Saddleworth, OL3 5NH Tel: 01457 810 391 | www.valcom.co.uk sales@valcom.co.uk Date of sale:...
  • Page 79 © Alphatech spol. s r.o. 2014-2015 version V1.2...

This manual is also suitable for:

Ip bold-txIp bold-txcIp bold-tkxIp bold-tkxc

Table of Contents