3
Parametres programming
Parametres programming is performed by ordinary WEB browser.
(Caution! version of IE V7 and lower are not supported).
3.1 WEB interface access
For successful display of WEB interface of IP BOLD door entry we go
through some details.
Field length - names, titles, codes, passwords have fix length 40 characters.
- URL and etc. have max length 255 characters
3.1.1 Before login
Before first start of IP BOLD door entry firstly check positions of DIP switch.
Each switches should be in positions as picture bellow.
1 – on
2 – off
3 – off
4 – off
Meaning of each switches:
1.
Always in on position.this switch is used in production or servis only.
2.
When is on during power supply start(or reset), then is setup up default
IP adress 192.168.1.250, operational position is off
3.
off, currently not used
4.
off, currently not used
You should also dedicate attention into which PC network you are
connected. Default door entry IP address is 192.168.1.250.
When is your PC in network setup also on segment 192.168.1.xxx then
might caused a problem in network just by same IP address etc.
192.168.1.250.
In this case we recommend temporarily disconnect device from network.
When your PC is setup to different network segment than 192.168.1.xxx
two possibilities are available:
1. In PC you have system Windows 7 or 8, then you can setup „network
setting" – „Protocol IP version 4" – „Property" – specify" and here add
IP address in PC segment of door entry for example. 192.168.1.10
2. Generally in PC setup you program temporarily own IP address.In PC
door entry segment for example 192.168.1.10. After change of door
entry IP address you have return setting in PC back.
26
IP BOLD
- installation and operating instructions