8.0 DEFAULT VALUES
Low Alarm Set point:
1.0
High Alarm Set point:
8.0
Low Cleaning Set point:
2.0
High Cleaning Set point:
4.0

Alarm Relay:

Ano
Cleaning Relay:
Cno
Units:
IN
Security Code:
000
9.0 DISPLAYS
Units:
Programmable for Inches Water or Kilopascals
Bargraph Display:
51 element tri-color LED analog ∆ Pressure bargraph
Green = Differential Pressure,
Red = Alarm set points
Yellow = Cleaning set points
Digital Display:
7-segment 3-digit Differential Pressure display, 0.3" tall
Range:
00.0 to 10.0" (00.0 to 02.5 KPa), flashes "00.0" when pressure is
approximately -0.5", flashes "ERR" when pressure is approximately -1.0",
flashes "10.0" when pressure is approximately 10.2" or greater.
Discrete LED Indicators:
10.0 ENVIRONMENTAL
Enclosure Rating:
Rated NEMA 4 for Front Panel Mount.
Operating Temperature Range:
Protection:
Conformal coating on PCB for humidity and vibration
Dustronix PS700 Operation Manual
Cleaning = Green
Alarm = Red/Yellow
32° to 150° Fahrenheit (0° to 65° Celsius)
Figure 2
Page 10
N a ti o n al C o n tro l s C o rp.
Phone 800-323-2593 • Fax 630-231-1377 • www.nationalcontrols.com
Dustronix PS700 Operation Manual
Figure 3
Page 11