UAZ PATRIOT Operation Manual page 57

Hide thumbs Also See for PATRIOT:
Table of Contents

Advertisement

outside the system reception signal range has exceeded 1000,
the system stops responding to control panel commands. In this
case the full system teaching procedure should be carried out.
In case of full system teaching, all previously recorded control
panel codes will be deleted, and new codes will be recorded in
their place. Full teaching is performed when one of the control
panels is lost and it is necessary to delete it from the system.
To log on the teaching mode, any RCP that was taught in the
system and the synchronization counter which is synchronized
with the control unit are needed. The RCP with which teaching
has been initiated becomes educative in this teaching session.
When the teaching procedure is violated, the system logs out
of the teaching mode without any results saved and the system
status indication
Full teaching is performed in the following order:
1. Deactivate system security system;
2. Leave one of the doors open;
3. Start up the ignition;
4. Max. 1.5 s after starting ignition, press button 4 on the
control panel to be taught and hold it pressed;
5. Wait until the system status signal device in the cluster
starts blinking fast, indicating the teaching process has started
(about 3 s after pressing button 4);
6. Max. 3 s after the indicator starts blinking, holding button
4 pressed, press button 2 one time. The system status signal
device stops blinking and is continuously lit. Release button 4;
Full system teaching
in the cluster goes out.
57
Fig. 3.15. Remote
control panel:
1 — screw; 2 — replace
battery

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

PickupCargo

Table of Contents