5446 RTU Setup
F-4
Procedure
From an SNMP workstation:
1. To load the MIB, access the Paradyne World Wide Web site:
http://www.paradyne.com
2. Select:
Service & Support
3. Enter the IP address of the RTU.
4. Press Options to change Set Community to Private.
5. Locate the MIB group pdn-ipinjection.
From a MIB browser, do a single set with a unique entry containing the required
fields. Refer to
Table F-1
Using the null entry:
Procedure
1. Change the Null entry by entering the IP address (ipInjectionAddress).
2. Change the mask by entering a subnet mask (ipInjectionMask).
3. Change the Type to Service Provider or Host (ipInjectionType).
4. Select Set.
5. Do a Get or Query to verify before continuing to the next entry.
Using the table index:
Procedure
1. Enter the three fields into the Index:
— ipInjectionType
— ipInjectionAddress
— ipInjectionMask
2. Enter the status value:
— ipInjectionStatus
3. Select Set.
If a null entry does not appear, the table is full. Delete entries from the table by
setting the ipInjectionStatus to invalid.
November 1997
MIBs
HotWire DSL
for IP injection group objects.
pdndce.mib
8000-A2-GB20-20