Paradyne 8540 User Manual page 108

Dslam for 8540 and 8546 dsl cards
Table of Contents

Advertisement

Monitoring the HotWire DSLAM
7-20
Table 7-7. Physical Layer Options (5 of 5)
DSL Error Stats
Displays the error performance (margin) rates for each of the DSL ports after selecting a
specific DSL port number. Margin is a measure of performance.
Enter port number one to four to see the fields for current 15-minute period (real time
count of events during the past 0 to 15 minutes), previous 15-minute period (data
updated every 15 minutes), previous one hour period (data updated every hour), and
24-hour period (data bucket updated every hour). A margin of 0 db equals an expected
-7
bit error rate of 10
. (The higher the margins, the fewer the errors.)
You may enter Ctrl-r at any time to reset counters.
Error Rate Definition:
dn margin – Measure of the noise margin on the specified port in the downstream
direction.
up margin – Measure of the noise margin on the specified port in the upstream
direction.
dn err rate – This statistic is not available for this release and an NA appears for each
time period.
up err rate – Block error rate in upstream direction. Error rate = bad blocks/good blocks
and is expressed as A x 10
dn err secs (dn err mins for Model 8540) – Count of the number of down error
seconds with at least one block error.
up err secs – (up err mins for Model 8540) – Count of the number of up error seconds
with at least one block error.
dn svr err sec – This statistic is not available for this release and an NA appears for
each time period.
up svr err sec – Count of the number of seconds with at least 800 block errors.
DSL Xmit Status (DSL Transmit Stats)
Displays the transmit and receive statistics for each of the DSL ports after selecting a
specific DSL port number.
Enter port number one to four to see the fields for current 15-minute period (real time
count of events during the past 0 to 15 minutes), previous 15-minute period (data
updated every 15 minutes), previous one hour period (data updated every hour), and
24-hour period (data updated every hour).
You may enter Ctrl-r at any time to reset counters.
dn xmit pwr – Measure of the power level of the downstream signal sent to the RTU (in
db).
up xmit pwr – Measure of the power level of the upstream signal sent to the RTU (in
db).
dn rx gain – Measure of how much amplification was applied to the signal received at
the RTU.
up rx gain – Measure of how much amplification was applied to the signal received at
the DSLAM port.
dn att est – Measure of the downstream transmission loss on the DSL line.
up att est – Measure of the upstream transmission loss on the DSL line.