Minor Alarms - Paradyne 8540 User Manual

Dslam for 8540 and 8546 dsl cards
Table of Contents

Advertisement

Diagnostics and Troubleshooting

Minor Alarms

8-8
Use Table 8-4 to determine the appropriate action to take for each Minor Alarm.
Table 8-4. Minor Alarms (1 of 2)
Failure Type
Action
Config Error:
1. Check the Selftest Results display by following the menu sequence:
Diagnostics
2. Do another Selftest (Reset) and check results.
– If the results are normal, the problem was transient. Log the
results.
– If Selftest results still show configuration corruption, there is a
card problem. The card's non-volatile RAM should be erased and
the configuration reentered. Perform a configuration download.
– If the configuration has not been saved, use reset and erase
NVRAM to force the card to the factory default. Enter the basic
default route to the MCC and reconfigure the card manually.
NOTE:
The following are minor alarms where thresholds have been exceeded and
are primarily indications of degraded quality on the DSL loop. They are not
necessarily related to problems with the DSL card.
Margin
If DSL speed is set to a Fixed Rate, you may choose to lower the
Threshold
speed in the direction indicated by the threshold alarm (Fixed Up
(A trap
Speed or Fixed Down Speed) to get a better Margin and improved
message sent if
error performance.
margin falls
If DSL speed is set to Rate Adaptive and the Margin Threshold is
below selected
> 0, then this alarm is a warning that the loop has degraded. The
value.)
actual bit rate should still be above 10
temporary due to high temperature or humidity/rain, or it may be
permanent due to high noise from additional digital circuits installed
in the same cable bundle.
If DSL speed is set to Rate Adaptive and the Margin Threshold is
< 0, then this alarm is a warning that the loop has seriously
degraded. The actual bit rate may be below 10
may be temporary or permanent. However, if it persists, the loop
may have to be reengineered for better performance by performing
one of the following:
– Remove bridge taps
– Change cable gauge on a cable section
– Run new cable
– Remove other noise-generating digital circuits from the cable
bundle
November 1997
Selftest.
-7
. This condition may be
-7
. This condition
8000-A2-GB20-20