Description
Sync ports (0, 1)
Power Consumption Specifications
The following table lists the power consumption specifications for a fully configured chassis.
Be sure that the chassis configuration complies with the required power budgets. Failure to properly verify
Caution
the configuration may result in an unpredictable state if one of the power units fails. Contact your local
sales representative for assistance.
Table 29: Power Consumption Specifications
Description
Power consumption
The following modules are supported on fixed ports on the Cisco ASR 9001 and Cisco ASR 9001-S:
• SFP-10G-ZR
• SFP-H10GB-ACU7M
• SFP-H10GB-ACU10M
• DWDM SFP10G-3033 through DWDM SFP10G-6141
• ONS-SC+-10G-C
Note
The fixed ports on the Cisco ASR 9001 and ASR 9001-S do not support FastEthernet and GigabitEthernet
transceivers.
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
124
Value
Can be configured as one of the following:
• BITS (Building Integrated Timing System) port
• J.211 or UTI (Universal Timing Interface) port
Value
400 W at 77°F (25°C)
425 W at 104°F (40°C)
450 W at 131°F (55°C)