Preparing for Installation
Table 5: RP AUX Port Signals
AUX Port Pin
1
2
3
4
5
6
7
8

Management LAN Ports Connection Guidelines

The RP has two RJ45 media-dependent interface (MDI) Ethernet management LAN ports: MGT LAN 0 and
MGT LAN 1
These ports are used for IEEE 802.3 10BASE-T (10 Mbps), IEEE 802.3u 100BASE-TX (100 Mbps), or
1000BASE-T (1000 Mbps) Ethernet connections.
The transmission speed of the management LAN ports is not user-configurable. The transmission speed is set
through an auto-sensing scheme on the RP; the speed is determined by the network to which that the Ethernet
port is connected. The combined total input rate of both MGT LAN 0 and MGT LAN 1 is about 12 Mbps.
Management port characteristics are:
• Maximum transmission unit (MTU) is fixed at 1514 and cannot be configured.
• Flow control is disabled and cannot be configured.
• Input unicast packets with an unknown destination address are filtered and dropped.
• Autonegotiation of port speed (10/100/1000) and duplex (full/half) is supported. Autonegotiation cannot
The following table lists the signals used on the Management LAN ports.
Table 6: RP Management LAN Port Signals
MGT LAN Port Pin
1
2
Signal
RTS
DTR
TxD
GND
GND
RxD
DSR
CTS
(Figure 23: Cisco ASR 9001 Router Front Panel
be disabled.
Input/Output
Output
Output
Output
Input
Input
Input
10Base-T, 100Base-TX Signal
Transmit+
Transmit–
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
Management LAN Ports Connection Guidelines
Description
Request to send
Data terminal ready
Transmit data
Signal ground
Signal ground
Receive data
Data set ready
Clear to send
Ports).
1000Base-T Signal
BI_DA+
BI_DA–