Ac Electrical Specifications - Cisco ASR 9001 Hardware Installation Manual

Hide thumbs Also See for ASR 9001:
Table of Contents

Advertisement

Technical Specifications
Description
Acoustic noise
Shock
Vibration

AC Electrical Specifications

Table 23: AC Electrical Specifications
Description
Power modules per system
Total AC input power
Rated input voltage
Note
Rated input line frequency
Input current rating
Source AC service requirement
Redundancy
For each AC power supply
module.
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
AC Electrical Specifications
Value
70 dB at 80.6°F (27°C) maximum
Operating (halfsine): 21 in/sec (0.53 m/sec)
Nonoperating (trapezoidal pulse): 20 G, 52 in/sec
(1.32 m/sec)
Note
G is a value of acceleration, where 1G equals
32.17 ft/sec2 (9.81 m/sec2).
Operating: 0.35 Grms from 3 to 500 Hz
Note
Grms is the root mean square value of
acceleration.
Nonoperating: 1.0 Grms from 3 to 500 Hz
Value
Up to two AC power modules per system
765 VA (volt-amps) per AC power supply(up to two
AC power supply modules per system)
100–240 VAC nominal (range: 90 to 264
VAC)220–240 VAC (UK)
50/60 Hz nominal (range: 47 to 63 Hz)50/60 Hz (UK)
15 A maximum at 100 VAC13 A maximum at 220
to 240 VRMS (UK)
15 A North America and Japan; 10 A international;
13 A UK
Power redundancy requirements vary, based on
system configuration (number and type of line cards,
etc). AC and DC powered systems are N+1 protected.
121

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asr 9001-s

Table of Contents