Modular Port Adapter (Mpa) Installation And Removal; Optical Device Installation And Removal - Cisco ASR 9001 Hardware Installation Manual

Hide thumbs Also See for ASR 9001:
Table of Contents

Advertisement

Installing Modules and Cables in the Chassis
If the bay is empty when the Cisco ASR 9001 Router modular line card (MLC) boots you can do the following:
If the MLC boots with a 20 GE MPA in the bay you can remove and then insert a replacement 20 GE MPA
If the MLC boots with a 4 10-GE MPA in the bay you can remove and then insert a replacement 4 10-GE
MPA
If the MLC boots with a 2 10-GE MPA in the bay you can remove and then insert a replacement 2 10-GE
MPA
Only replacement with same types of MPA is supported by Managed OIR and Hard OIR. An empty bay
Note
during the Cisco ASR 9001 Router modular line card (MLC) bootup defaults to 20 GE MPA mode.

Modular Port Adapter (MPA) Installation and Removal

This section provides step-by-step instructions for removing and installing a modular port adapter (MPA).
When performing these procedures, wear a grounding wrist strap to avoid ESD damage to the modular
Caution
port adapter (MPA). Some platforms have an ESD connector for attaching the wrist strap. Do not directly
touch the midplane or backplane with your hand or any metal tool, or you could shock yourself.
To remove and install a modular port adapter (MPA), perform these steps:
Procedure
Step 1
To insert the MPA, carefully slide the MPA all the way until it stops.
Note
Step 2
To fully seat the MPA, use a number 2 Phillips screwdriver to tighten the jackscrew on the MPA.
Note
Step 3
To remove the MPA, use a number 2 Phillips screwdriver to loosen the lock screw on the MPA. Make sure
that the cables are disconnected from the MPA first.
Step 4
Grasp the MPA and pull the MPA from the slot.

Optical Device Installation and Removal

Any contamination of the fiber connection can cause failure of the component or failure of the whole system.
A particle that partially or completely blocks the core generates strong back reflections, which can cause
Insert a 20 GE MPA
◦ Remove and then insert a replacement 20 GE MPA
The modular port adapter (MPA) will slide easily into the slot if it is properly aligned on the tracks.
If MPA does not slide easily, do NOT force it. Remove the MPA and reposition it, paying close
attention to engaging it on the tracks.
Avoid over torquing the modular port adapter (MPA) jackscrew when installing the MPA. Tighten
the jackscrew on the MPA to a torque of 17 +/-1 inch-pound. Do not use a power screwdriver to
tighten the MPA jackscrew.
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
Modular Port Adapter (MPA) Installation and Removal
69